Vickers D03 Solenoid Valve

859177

Vickers D03 Solenoid Valve
Item #101922791
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Port T Code 6
Port T Pressure Rating 3000 psi
Electrical Options None
Temperature Range [Min] -4 °F
Response Time 15 to 23 ms
Manual Override Option Code None
Spool Shift Timing N/A
Model No. DG4V 3 6C M U A6 60
Spool Code 6
Coil Rating Code A
Port Restrictor Plug Code None
Solenoid Double
Cycle Rate [Max] N/A
Mounting Subplate/Manifold Mount
Actuation Identification Solenoid A, Solenoid B
Body Material Gray Iron
Actuator Type Solenoid
Reducer Module No
Response Type Standard Response
Spool Spring Arrangement Code C
Solenoid Indicator Lights Code None
Crossover P Blocked, A or B to T
Operation Solenoid Operated
Surge Suppressor/Damper Code None
Solenoid Code A
Rated Flow [Max] 20 gal/min
Compatible Fluids Petroleum Oil
Pilot/Drain None
Coil Type Code U
Spool Indicator Switch Code None
Design No. 60
Electrical Connector Code None
Voltage & Frequency 110 VAC - 50 Hz
Valve Type High-Performance
Manual Override Plain Override
Mechanical Options None
Electrical Connection DIN 43650
Pilot Valve Type N/A
Housing Code None
Temperature Range [Max] 158 °F
Center Position P Blocked, A & B to T
Pressure Port Check Valve Pressure N/A
Indicator Lights No
No. of Stages Single Stage
Performance High Performance
EN Code None
Port Restrictor Plugs None
Function Code 6
Solenoid Energization Code None
AC/DC AC
Tank Port Rating 3046
Function 3-Position Spring Centered
Overrides No Overrides
NFPA Size D03
Fluid Cleanliness 19/17/14 micron
Pressure [Max] 5000 psi
Coil Type ISO 4400
Surge Suppressor/Damper None
Seal Material Buna-N
Leakage Standard Performance
Weight 5.0 LB