Vickers D03 Solenoid Valve

565466

Vickers D03 Solenoid Valve
Item #102028347
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Function 3-Position Detented
No. of Stages Single Stage
Reducer Module No
Center Position P Blocked, A & B to T
Temperature Range [Min] -4 °F
Electrical Connector Code None
Mounting Subplate/Manifold Mount
Seal Material Buna-N
Tank Port Rating 3046
Manual Override Option Code None
Port T Pressure Rating 3000 psi
Solenoid Indicator Lights Code None
Coil Rating Code H
Spool Spring Arrangement Code N
Solenoid Code H
Indicator Lights No
EN Code None
Leakage Standard Performance
Mechanical Options None
Pressure [Max] 5000 psi
Port Restrictor Plug Code None
AC/DC DC
Port Restrictor Plugs None
Crossover P Blocked, A or B to T
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Max] 158 °F
Watt Rating 30 W
Electrical Options None
Actuator Type Solenoid
Port T Code 7
Electrical Connection DIN 43650
Spool Indicator Switch Code None
Model No. DG4V 3 6N M U H7 60
Coil Type Code U
Spool Code 6
Spool Shift Timing N/A
Response Time 28 to 45 ms
Surge Suppressor/Damper None
Operation Solenoid Operated
NFPA Size D03
Rated Flow [Max] 20 gal/min
Body Material Gray Iron
Manual Override Plain Override
Housing Code None
Pilot Valve Type N/A
Solenoid Energization Code None
Fluid Cleanliness 19/17/14 micron
Response Type Standard Response
Function Code 6
Solenoid Double
Surge Suppressor/Damper Code None
Pressure Port Check Valve Pressure N/A
Cycle Rate [Max] N/A
Valve Type High-Performance
Compatible Fluids Petroleum Oil
Performance High Performance
Design No. 60
Voltage & Frequency 24 VDC
Overrides No Overrides
Pilot/Drain None
Coil Type ISO 4400
Weight 5.0 LB