Skip to content Skip to navigation menu
Vickers02-356635

02-356635

Vickers D10 Solenoid Valve
Item #101907270
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers02-356635
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Reducer Module N/A
Response Type Standard Response
Surge Suppressor/Damper None
NFPA Size D10
Indicator Lights No
Coil Type Code U
Reducer Module Code None
Port Restrictor Plugs None
Valve Type Standard-Duty
Electrical Connector Code None
Electrical Options Code None
Mechanical Options Adjust Pilot Chokes on Both Ends, Adjust Stroke on Both Ends
Pressure [Max] 5000 psi
AC/DC DC
Design No. 10
Spool Control Modification Code 3
Solenoid Indicator Lights Code None
Spool Code 2
Pilot Pressure Code None
Pilot Pressure [Max] 3000 psi
Pilot Drain Code None
Assembly Code None
Solenoid Double
Solenoid Energization Code None
Operation Pilot Operated
Voltage & Frequency 24 VDC
Port T Pressure Rating 3000 psi
Model No. DG5V-10-H-2C-3-M-U-H-10
Pilot Valve Type CETOP 3, High Performance
Rated Flow [Max] 290 gal/min
Response Type Code None
Center Position All Ports Blocked
Port Restrictor Plug Code None
Electrical Options None
Coil Rating Code H
Actuator Type Solenoid
Manual Override Plain Override
Coil Type DIN 43650
Spool Spring Arrangement Code C
Gauge Port SAE-4
Pilot Valve Type Code H
EN Code None
Housing Code None
Pressure Port Check Valve Pressure N/A
Electrical Connection No Connector
Function 3-Position Spring Centered
Manual Override Option Code None
Gauge Ports Code None
Pilot/Drain External Pilot/Internal Drain
Crossover All Ports Blocked
Surge Suppressor/Damper Code None
Seal Material Buna-N
Tank Port Rating 3000
Pressure Port Check Valve Code None
Overrides Plain Override Solenoid Ends
Weight 100.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison