Vickers D03 Solenoid Valve

02-354202

Vickers D03 Solenoid Valve
Item #101923221
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
Indicator Lights Yes
Spool Shift Timing N/A
Fluid Cleanliness 19/17/14 micron
EN Code None
Reducer Module No
Mounting Subplate/Manifold Mount
Solenoid Indicator Lights Code L
Pilot/Drain None
Port Restrictor Plugs None
Coil Type Code F
Surge Suppressor/Damper Code None
Cycle Rate [Max] N/A
Temperature Range [Min] -4 °F
NFPA Size D03
Response Type Standard Response
Housing Code W
Seal Material Buna-N
Manual Override Option Code None
Solenoid Single
Port Restrictor Plug Code None
Function 2-Position Spring Offset, End To Center, Left Hand Build
Coil Rating Code B
Pressure Port Check Valve Pressure N/A
Performance High Performance
Pressure [Max] 5000 psi
Spool Indicator Switch Code None
Rated Flow [Max] 20 gal/min
Solenoid Code B
Center Position All Ports Blocked
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Compatible Fluids Petroleum Oil
Response Time 15 to 23 ms
Manual Override Plain Override
Valve Type High-Performance
No. of Stages Single Stage
Pilot Valve Type N/A
Crossover All Ports Blocked
Overrides No Overrides
Spool Spring Arrangement Code B
Body Material Gray Iron
Solenoid Energization Code None
Leakage Standard Performance
Model No. DG4V-3-2BL-M-FTWL-B6-60
Temperature Range [Max] 158 °F
Surge Suppressor/Damper None
AC/DC AC
Electrical Connection Wired Terminal Block
Electrical Options None
Port T Pressure Rating 3000 psi
Design No. 60
Tank Port Rating 3046
Actuation Identification Solenoid A
Operation Solenoid Operated
Actuator Type Solenoid
Port T Code 6
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Code 2
Mechanical Options None
Electrical Connector Code T
Function Code 2
Weight 5.0 LB