- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
Pressure Port Check Valve Code | None |
Fluid Cleanliness | 19/17/14 micron |
Overrides | Plain Override Solenoid Ends |
Pilot/Drain | External Pilot/Internal Drain |
Electrical Options Code | None |
Valve Type | Standard-Duty |
Pressure Port Check Valve Pressure | N/A |
Pilot Valve Type | CETOP 3, High Performance |
NFPA Size | D08 |
Port T Pressure Rating | 5000 psi |
Coil Type Code | F |
Surge Suppressor/Damper Code | None |
Port Restrictor Plug Code | None |
Mounting | Subplate/Manifold Mount |
Pilot Drain Code | None |
Function | 3-Position Spring Centered |
Seal Material | Buna-N |
Response Type | Standard Response |
Spool Control Modification Code | None |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Pressure [Max] | 5000 psi |
Electrical Options | None |
Pilot Valve Type Code | H |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Spool Code | 6 |
Solenoid Indicator Lights Code | None |
Solenoid Energization Code | None |
Response Type Code | None |
Center Position | P Blocked, A & B to T |
Crossover | P Blocked, A or B to T |
Leakage | Standard Performance |
Spool Spring Arrangement Code | C |
Actuator Type | Solenoid |
Coil Rating Code | B |
Manual Override | Plain Override |
Port Restrictor Plugs | None |
Housing Code | W |
Gauge Ports Code | None |
Reducer Module | No |
Compatible Fluids | Petroleum Oil |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Tank Port Rating | 5000 |
AC/DC | AC |
Electrical Connection | No Connector |
Surge Suppressor/Damper | None |
Indicator Lights | No |
Spool Indicator Switch Code | None |
Mechanical Options | None |
EN Code | None |
No. of Stages | Two Stage |
Design No. | 10 |
Performance | High Performance |
Electrical Connector Code | None |
Mechanical Options Code | None |
Body Material | Gray Iron |
Manual Override Option Code | None |
Gauge Port | SAE-4 |
Reducer Module Code | None |
Model No. | DG5V-8-H-6C-M-FW-B-10 |
Operation | Pilot Operated |
Pilot Pressure Code | None |
Solenoid | Double |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Rated Flow [Max] | 175 gal/min |
Weight | 35.0 LB |