Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-319614

Vickers D03 Solenoid Valve
Item #102084935
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Indicator Lights No
Pressure Port Check Valve Pressure N/A
Manual Override Plain Override
Model No. DG4V 3 6C H M U BL6 60
Solenoid Code BL
Body Material Gray Iron
Response Type Standard Response
EN Code None
Actuator Type Solenoid
Spool Shift Timing N/A
Mechanical Options None
Port Restrictor Plugs None
Pilot/Drain None
Performance High Performance
Surge Suppressor/Damper Code None
Seal Material Buna-N
Coil Type Code U
Port T Code 6
Temperature Range [Min] -4 °F
Electrical Connector Code None
Leakage Standard Performance
Mounting Subplate/Manifold Mount
Compatible Fluids Petroleum Oil
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Rating Code BL
Spool Code 6
Tank Port Rating 3046
Valve Type High-Performance
Surge Suppressor/Damper None
Spool Spring Arrangement Code C
Overrides No Overrides
Solenoid Double
Coil Type ISO 4400
Manual Override Option Code H
Response Time 15 to 23 ms
Port Restrictor Plug Code None
Electrical Connection DIN 43650
AC/DC AC
Rated Flow [Max] 20 gal/min
Temperature Range [Max] 158 °F
Spool Indicator Switch Code None
Solenoid Energization Code None
Pilot Valve Type N/A
NFPA Size D03
Function 3-Position Spring Centered
Operation Solenoid Operated
Fluid Cleanliness 19/17/14 micron
Port T Pressure Rating 3000 psi
Design No. 60
Electrical Options None
Pressure [Max] 5000 psi
Reducer Module No
Solenoid Indicator Lights Code None
Function Code 6
Cycle Rate [Max] N/A
Center Position P Blocked, A & B to T
No. of Stages Single Stage
Crossover P Blocked, A or B to T
Housing Code None
Actuation Identification Solenoid A, Solenoid B
Weight 5.0 LB