Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-311430

Vickers D03 Solenoid Valve
Item #102088980
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Temperature Range [Min] -4 °F
Response Time 15 to 23 ms
Manual Override Plain Override
Cycle Rate [Max] N/A
EN Code None
Pilot/Drain None
Coil Type Code F
Mounting Subplate/Manifold Mount
Indicator Lights No
Design No. 60
Solenoid Code B
Function Code 2
Body Material Gray Iron
Spool Code 2
Temperature Range [Max] 158 °F
Port Restrictor Plug Code None
Model No. DG4V 3 2A M FTW B6 60
Electrical Connection Wired Terminal Block
Surge Suppressor/Damper None
Mechanical Options None
Port T Code 6
AC/DC AC
Performance High Performance
NFPA Size D03
Solenoid Energization Code None
Surge Suppressor/Damper Code None
Spool Shift Timing N/A
Manual Override Option Code None
Valve Type High-Performance
Leakage Standard Performance
Tank Port Rating 3046
Pressure [Max] 5000 psi
Spool Indicator Switch Code None
Seal Material Buna-N
Coil Rating Code B
Port Restrictor Plugs None
No. of Stages Single Stage
Overrides No Overrides
Rated Flow [Max] 20 gal/min
Solenoid Single
Electrical Options None
Electrical Connector Code T
Function 2-Position Spring Offset, End to End
Reducer Module No
Response Type Standard Response
Housing Code W
Actuation Identification Solenoid B
Fluid Cleanliness 19/17/14 micron
Port T Pressure Rating 3000 psi
Center Position All Ports Blocked
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot Valve Type N/A
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Solenoid Indicator Lights Code None
Crossover All Ports Blocked
Pressure Port Check Valve Pressure N/A
Compatible Fluids Petroleum Oil
Actuator Type Solenoid
Spool Spring Arrangement Code A
Operation Solenoid Operated
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison