Vickers D03 Solenoid Valve

02-110359

Vickers D03 Solenoid Valve
Item #101850840
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Temperature Range [Min] -4 °F
Solenoid Double
Model No. DG4V36CMFTWLB660
Manual Override Option Code None
NFPA Size D03
Valve Type High-Performance
Pilot/Drain None
EN Code None
Electrical Connection Wired Terminal Block
Actuator Type Solenoid
Operation Solenoid Operated
Spool Code 6
Port Restrictor Plugs None
Solenoid Energization Code None
Spool Shift Timing N/A
Pressure Port Check Valve Pressure N/A
Tank Port Rating 3046
Watt Rating 20 W
Rated Flow [Max] 20.00 gal/min
Mechanical Options None
Design No. 60
Coil Type Code F
Spool Indicator Switch Code None
Pressure [Max] 5,075 psi
Mounting Manifold Mount
Overrides No Overrides
Manufacturer Part No. DG4V 3 6C M FTWL B6 60
Coil Rating Code B
Pilot Valve Type N/A
Port T Pressure Rating 3000 psi
Surge Suppressor/Damper None
Function Code 6
Center Position P Blocked, A & B to T
Indicator Lights Yes
No. of Stages Single Stage
Cycle Rate [Max] 0
Response Type Standard Response
Voltage & Frequency 110/120 VAC - 50/60 Hz
Crossover P Blocked, A or B to T
Port T Code 6
Manual Override Plain Override
AC/DC AC
Electrical Connector Code T
Spool Center Condition A Port and Double Offset sensing switch on B Port
Rated Flow 21.00 gal/min
Electrical Options None
Body Material Gray Iron
Solenoid Code B
Seal Material Viton
Housing Code W
Reducer Module No
Temperature Range [Max] 158 °F
Function 3-Position, 4-Way, Spring Centered
Compatible Fluids Phosphate Ester Fluids
Surge Suppressor/Damper Code None
Port Restrictor Plug Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Fluid Cleanliness 19/17/14 micron
Leakage Standard Performance
Solenoid Indicator Lights Code L
Spool Spring Arrangement Code C
Performance Standard Performance
Weight 4.6 LB