Vickers D03 Solenoid Valve

02-110345

Vickers D03 Solenoid Valve
Item #101967667
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plugs None
Mounting Subplate/Manifold Mount
Pressure [Max] 5000 psi
Leakage Standard Performance
Manual Override Option Code H
Function Code 2
Cycle Rate [Max] N/A
Function 3-Position Spring Centered
Coil Rating Code B
Spool Shift Timing N/A
Spool Code 2
Spool Indicator Switch Code None
Coil Type ISO 4400
Seal Material Buna-N
Pilot/Drain None
Valve Type High-Performance
Pressure Port Check Valve Pressure N/A
EN Code None
Mechanical Options None
Solenoid Double
Overrides No Overrides
Performance High Performance
Port T Pressure Rating 3000 psi
Solenoid Energization Code None
Coil Type Code U
Surge Suppressor/Damper None
Port T Code 6
Port Restrictor Plug Code None
Center Position All Ports Blocked
Body Material Gray Iron
Actuator Type Solenoid
Solenoid Code B
Reducer Module No
Indicator Lights No
Surge Suppressor/Damper Code None
Electrical Options None
Rated Flow [Max] 20 gal/min
Temperature Range [Min] -4 °F
AC/DC AC
No. of Stages Single Stage
Electrical Connection DIN 43650
Temperature Range [Max] 158 °F
Crossover All Ports Blocked
Actuation Identification Solenoid A, Solenoid B
Operation Solenoid Operated
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot Valve Type N/A
Design No. 60
Model No. DG4V 3 2C H M U B6 60
Electrical Connector Code None
Response Type Standard Response
Tank Port Rating 3046
NFPA Size D03
Manual Override Plain Override
Solenoid Indicator Lights Code None
Compatible Fluids Petroleum Oil
Housing Code None
Response Time 15 to 23 ms
Spool Spring Arrangement Code C
Weight 5.0 LB