Vickers D03 Solenoid Valve

02-109978

Vickers D03 Solenoid Valve
Item #101950047
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
Manual Override Option Code None
Pilot Valve Type N/A
NFPA Size D03
Solenoid Double
Port T Code 7
Spool Spring Arrangement Code C
Spool Shift Timing N/A
Pressure [Max] 5000 psi
Crossover P Blocked, A or B to T
Port Restrictor Plugs None
Electrical Options None
Port Restrictor Plug Code None
No. of Stages Single Stage
Spool Center Condition A Port and Double Offset sensing switch on B Port
Cycle Rate [Max] N/A
Overrides No Overrides
Actuator Type Solenoid
Tank Port Rating 3046
Solenoid Indicator Lights Code None
Response Type Standard Response
Housing Code None
Reducer Module No
Coil Type ISO 4400 (Din 43650) Connector
Surge Suppressor/Damper Code None
Center Position P Blocked, A & B to T
Spool Indicator Switch Code None
Manual Override Plain Override
EN Code None
Indicator Lights No
Surge Suppressor/Damper None
Electrical Connector Code None
Model No. DG4V 3 6C M U HL7 60
Performance Standard Performance
Solenoid Code HL
Operation Solenoid Operated
Solenoid Energization Code None
Design No. 60
Function Code 6
Coil Type Code U
Voltage & Frequency 24 VDC
Body Material Gray Iron
Leakage Standard Performance
Watt Rating 18 W
Temperature Range [Min] -4 °F
Mounting Subplate/Manifold Mount
Function 3-Position Spring Centered
Mechanical Options None
Pilot/Drain None
Seal Material Viton
Electrical Connection DIN 43650
AC/DC DC
Valve Type High-Performance
Compatible Fluids Phosphate Ester Fluids
Spool Code 6
Coil Rating Code HL
Temperature Range [Max] 158 °F
Port T Pressure Rating 3000 psi
Fluid Cleanliness 19/17/14 micron
Pressure Port Check Valve Pressure N/A
Rated Flow [Max] 20 gal/min
Weight 4.48 LB