Vickers Pressure Control Cartridge Valve
Item #104165492
  • Pressure Control Valve
  • Pressure Relief Valve Type
  • RV3A-10 Series
  • Cartridge Only Port Type
  • Direct Acting Operation
Vickers by Danfoss307AA00045A
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Pressure Control Valve
  • Pressure Relief Valve Type
  • RV3A-10 Series
  • Cartridge Only Port Type
  • Direct Acting Operation
Valve Material Cartridge only
No. of Valve Ports 2
Seal Material Viton
Installation Screw-in Cartridge
Valve Torque into Cavity 47 to 54 Nm
Adjustment Type Factory Set
Type Pressure Relief Valve
Recommend Filtration Level 18/16/13 microns
Temperature Range [Min] -40 °F
Leakage 0.25 cc/min
No. of Housing Ports 2
Cavity C-10-2
Operation Direct Acting
Style Poppet
Flow [Max] 20 gal/min
Operating Pressure [Max] 3626 psi
Series RV3A-10
Pressure Setting 348 psi
Operating Pressure [Min] 100 psi
Pilot Ratio 100:1
Temperature Range [Max] 248 °F
Pressure [Max] 3626 psi
Port Type Cartridge Only
Model No. RV3A-10V-F-0-6/3
Weight 0.0 LB