Skip to content Skip to navigation menu
Vickers by Danfoss02-401115

02-401115

Vickers D08 Solenoid Valve
Item #110393245
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Spring Centered Function
Vickers by Danfoss02-401115
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Spring Centered Function
Compatible Fluids Petroleum Oil
Temperature Range [Min] -40 °F
Indicator Lights Yes
Body Material Ductile Iron
AC/DC AC
Fluid Cleanliness 19/17/14 micron
Manual Override Plain Override
Actuation Identification Solenoid A, Solenoid B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Rated Flow [Max] 175 gal/min
Pressure [Max] 5000 psi
Reducer Module No
No. of Stages Two Stage
Temperature Range [Max] 230 °F
Spool Spring Arrangement Code C
Voltage & Frequency 110/120 VAC - 50/60 Hz
Model No. DG5V-8-H-0C-M-FWL-B-10-EN21
Function Spring Centered
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
NFPA Size D08
Seal Material Buna-N
Pilot/Drain Internal Pilot/External Drain
Performance High Performance
Actuator Type Solenoid
Leakage High Performance
Operation Pilot Operated
Mounting Subplate/Manifold Mount
Weight 33.075 LB