Skip to content Skip to navigation menu
Vickers by Danfoss02-399327

02-399327

Vickers D08 Solenoid Valve
Item #105170939
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Spring Centered Function
Vickers by Danfoss02-399327
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Spring Centered Function
Temperature Range [Max] 230 °F
Function Spring Centered
Pilot/Drain External Pilot/External Drain
Model No. DG5V-8-S-0C-2-E-M-FPA5WL-B-10
Leakage Standard Performance
Fluid Cleanliness 19/17/14 micron
Voltage & Frequency 110/120 VAC - 50/60 Hz
Rated Flow [Max] 175 gal/min
NFPA Size D08
AC/DC AC
Temperature Range [Min] -40 °F
Actuator Type Solenoid
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Connection Five Pin Connector
Body Material Ductile Iron
Reducer Module No
Seal Material Buna-N
Operation Pilot Operated
Mounting Subplate/Manifold Mount
Compatible Fluids Petroleum Oil
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Actuation Identification Solenoid A, Solenoid B
Pressure [Max] 5000 psi
Performance Standard Performance
No. of Stages Two Stage
Indicator Lights Yes
Manual Override Plain Override
Spool Spring Arrangement Code C
Weight 0.0 LB