Vickers by Danfoss02-393295

02-393295

Vickers D08 Solenoid Valve
Item #101998268
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-393295
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Mixing grid coupling components from different manufacturers may cause premature failure and possible personal injury or property damage from flying debris
Electrical Connector Code None
Pilot Valve Type CETOP 3, Standard Performance
Operation Pilot Operated
Pilot/Drain External Pilot/Internal Drain
Response Type Code None
Seal Material Buna-N
Pilot Drain Code T
NFPA Size D08
AC/DC AC
Mechanical Options Code None
Pressure Port Check Valve Pressure 5 psi
Spool Spring Arrangement Code C
Electrical Connection No Connector
Manual Override Plain Override
Housing Code W
Mechanical Options None
Surge Suppressor/Damper Code None
Spool Control Modification Code None
Electrical Options None
Coil Type Code F
Pilot Pressure Code None
Solenoid Indicator Lights Code None
Reducer Module Code None
Spool Code 3
Indicator Lights No
Port Restrictor Plug Code None
Solenoid Double
Port Restrictor Plugs None
Pressure Port Check Valve Code K
Overrides Plain Override Solenoid Ends
Gauge Port SAE-4
Voltage & Frequency 110/120 VAC - 50/60 Hz
Valve Type Standard-Duty
Spool Indicator Switch Code None
Reducer Module N/A
Design No. 10
Crossover All Ports Blocked, or P & B Blocked, A to T
Port T Pressure Rating 5000 psi
EN Code None
Coil Rating Code B
Actuator Type Solenoid
Surge Suppressor/Damper None
Manual Override Option Code None
Function 3-Position Spring Centered
Response Type Standard Response
Rated Flow [Max] 185 gal/min
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Tank Port Rating 5000
Gauge Ports Code None
Pilot Valve Type Code S
Solenoid Energization Code None
Center Position P & B Blocked, A to T
Electrical Options Code None
Pressure [Max] 5000 psi
Model No. DG5V-8-S-3C-T-K-M-FW-B-10
Weight 35.0 LB