Vickers by Danfoss02-364207

02-364207

Vickers D05 Solenoid Valve
Item #101907774
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-364207
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • Series 02 two-stage directional valves are designed to meet the requirements of high performance, precision industrial hydraulic systems operating at pressure to 210 bar (3,000 psi) and flows to 130 l/min (34 U.S. gpm), depending on spool type.

features

  • Tapered main spool lands which permit faster operation with less hydraulic shock
  • Advanced design pilot valves provide reduced power consumption without any sacrifice of valve performance
  • Quiet, long-life solenoids can be quickly replaced without disturbing the hydraulic circuitry for easy maintenance
AC/DC AC
Spool Indicator Switch Code None
EN Code None
Seal Material Buna-N
Pilot Pressure Code None
No. of Stages Two Stage
Spool Code 31
Coil Type Code F
NFPA Size D05
Tank Port Rating 1450
Design No. 20
Solenoid Energization Code None
Function 3-Position Spring Centered
Manual Override Plain Override
Solenoid Indicator Lights Code None
Spool Control Modification Code None
Crossover All Ports Blocked
Spool Spring Arrangement Code C
Electrical Connector Code None
Rated Flow [Max] 30 gal/min
Mounting Screw Option Code None
Pilot/Drain Internal Drain
Pilot Valve Type N/A
Surge Suppressor/Damper None
Pressure Port Check Valve Pressure N/A
Port T Pressure Rating 1450 psi
Voltage & Frequency 110/120 VAC - 50/60 Hz
Actuation Identification Solenoid A, Solenoid B
Valve Type Standard-Duty
Pilot Pressure [Min] 75 psi
Coil Rating Code B
Electrical Options None
Model No. DG5S4-02-31C-T-M-FW-B5-20
Solenoid Double
Pilot Pressure [Max] 3000 psi
Leakage Standard Performance
Mechanical Options None
Body Material Gray Iron
Indicator Lights No
Response Type Code None
Pilot Drain Code T
Pressure Port Check Valve Code None
Port Restrictor Plug Code None
Manual Override Option Code None
Operation Solenoid Operated
Temperature Range [Min] -0.4 °F
Temperature Range [Max] 150.8 °F
Reducer Module N/A
Port Restrictor Plugs None
Electrical Connection No Connector
Overrides Plain Override Solenoid Ends
Housing Code W
Response Type Standard Response
Mounting Subplate/Manifold Mount
Center Position P & A Blocked, B to T
Actuator Type Solenoid
Pilot Valve Tank Pressure Rating Code 5
Coil Type 1/2 in NPT Thread Wiring Housing
Pressure [Max] 3000 psi
Assembly Code None
Fluid Cleanliness 19/17/14 micron
Electrical Options Code None
Weight 13.0 LB