Vickers by Danfoss02-362304

02-362304

Vickers D08 Solenoid Valve
Item #101909440
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-362304
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Overrides Plain Override Solenoid Ends
Reducer Module Code None
Reducer Module N/A
Solenoid Indicator Lights Code L
Actuator Type Solenoid
Response Type Standard Response
Function 3-Position Spring Centered
Solenoid Double
Solenoid Energization Code None
Pilot/Drain External Pilot/Internal Drain
Mechanical Options Code None
Pressure [Max] 5000 psi
Crossover P Blocked, A or B to T
Model No. DG5V-8-H-6C-E-M-FTWL-B-10
Indicator Lights Yes
AC/DC AC
Electrical Connection Wired Terminal Block
Port Restrictor Plug Code None
Port T Pressure Rating 5000 psi
Surge Suppressor/Damper None
Spool Indicator Switch Code None
Pilot Drain Code None
Spool Control Modification Code None
Coil Rating Code B
Spool Code 6
Spool Spring Arrangement Code C
Electrical Connector Code T
Manual Override Option Code None
Gauge Ports Code None
Pressure Port Check Valve Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure Port Check Valve Pressure N/A
Design No. 10
Rated Flow [Max] 185 gal/min
Seal Material Buna-N
Electrical Options Code None
Operation Pilot Operated
NFPA Size D08
EN Code None
Surge Suppressor/Damper Code None
Manual Override Plain Override
Gauge Port SAE-4
Pilot Valve Type Code H
Valve Type Standard-Duty
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pilot Pressure Code E
Mechanical Options None
Center Position P Blocked, A & B to T
Pilot Valve Type CETOP 3, High Performance
Response Type Code None
Coil Type Code F
Housing Code W
Tank Port Rating 5000
Electrical Options None
Port Restrictor Plugs None
Weight 35.0 LB