Vickers D03 Solenoid Valve

02-361858

Vickers D03 Solenoid Valve
Item #101908363
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Solenoid Indicator Lights Code None
AC/DC AC
Compatible Fluids Petroleum Oil
Solenoid Code B
Body Material Gray Iron
Function Code 6
NFPA Size D03
Temperature Range [Min] -4 °F
Port Restrictor Plug Code None
Response Time 15 to 23 ms
Spool Spring Arrangement Code C
Tank Port Rating 3046
Cycle Rate [Max] N/A
Overrides No Overrides
EN Code EN21
Response Type Standard Response
Manual Override Plain Override
Solenoid Energization Code V
Coil Type Code F
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Code 6
Rated Flow [Max] 20 gal/min
Port Restrictor Plugs None
Center Position P Blocked, A & B to T
Surge Suppressor/Damper None
Solenoid Double
Electrical Connection No Connector
Mechanical Options None
Pressure Port Check Valve Pressure N/A
Spool Code 6
Actuation Identification Solenoid A, Solenoid B
Model No. DG4V-3-6C-VM-FW-B6-60-EN21
Electrical Connector Code None
Valve Type High-Performance
Spool Shift Timing N/A
Performance High Performance
Operation Solenoid Operated
Indicator Lights No
Surge Suppressor/Damper Code None
Reducer Module No
Crossover P Blocked, A or B to T
Function 3-Position Spring Centered
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Coil Rating Code B
Pilot/Drain None
Leakage Standard Performance
Design No. 60
Actuator Type Solenoid
Fluid Cleanliness 19/17/14 micron
Spool Indicator Switch Code None
Electrical Options None
Manual Override Option Code None
Temperature Range [Max] 158 °F
Pressure [Max] 5000 psi
Port T Pressure Rating 3000 psi
Housing Code W
Pilot Valve Type N/A
Seal Material Buna-N
No. of Stages Single Stage
Mounting Subplate/Manifold Mount
Weight 5.0 LB