Vickers by Danfoss02-357158

02-357158

Vickers D08 Solenoid Valve
Item #101907011
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-357158
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Gauge Ports Code None
Model No. DG5V-8-S-0A-E-T-M-U-B-10
Coil Type ISO 4400 (Din 43650) Connector
Compatible Fluids Petroleum Oil
Tank Port Rating 5000
Solenoid Indicator Lights Code None
Fluid Cleanliness 19/17/14 micron
Mechanical Options Code None
Design No. 10
Pilot Valve Type Code S
Seal Material Buna-N
Response Type Standard Response
Pressure Port Check Valve Code None
Response Type Code None
Coil Type Code U
Reducer Module Code None
Pilot/Drain External Pilot/Internal Drain
Actuator Type Solenoid
Function 2-Position Spring Offset
Crossover All Ports Open
Port T Pressure Rating 5000 psi
Temperature Range [Min] -40 °F
Leakage Standard Performance
Rated Flow [Max] 175 gal/min
Overrides Plain Override Solenoid Ends
Pilot Valve Type CETOP 3, Standard Performance
Center Position All Ports Open
Indicator Lights No
Mechanical Options None
Temperature Range [Max] 230 °F
Performance Standard Performance
Pressure Port Check Valve Pressure N/A
Port Restrictor Plugs None
Electrical Connector Code None
Pilot Pressure Code E
Voltage & Frequency 110/120 VAC - 50/60 Hz
Manual Override Option Code None
No. of Stages Two Stage
Electrical Connection No Connector
Gauge Port SAE-4
Solenoid Energization Code None
Manual Override Plain Override
EN Code None
Operation Pilot Operated
AC/DC AC
Reducer Module No
Valve Type Standard-Duty
Spool Control Modification Code None
Pressure [Max] 5000 psi
Spool Indicator Switch Code None
Solenoid Single
Mounting Subplate/Manifold Mount
Surge Suppressor/Damper None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Coil Rating Code B
Spool Code 0
Housing Code None
NFPA Size D08
Spool Spring Arrangement Code A
Electrical Options None
Port Restrictor Plug Code None
Surge Suppressor/Damper Code None
Pilot Drain Code T
Body Material Ductile Iron
Actuation Identification Solenoid B
Electrical Options Code None
Weight 35.0 LB