- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Single Solenoid
- 2-Position Spring Offset Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Reducer Module Code | None |
| Mechanical Options | None |
| No. of Stages | Two Stage |
| Solenoid | Single |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Spool Code | 2 |
| Coil Type Code | U |
| Electrical Connector Code | None |
| NFPA Size | D08 |
| Tank Port Rating | 5000 |
| Surge Suppressor/Damper Code | None |
| Spool Control Modification Code | None |
| Function | 2-Position Spring Offset |
| Body Material | Ductile Iron |
| Indicator Lights | No |
| Mechanical Options Code | None |
| Manual Override Option Code | None |
| Solenoid Indicator Lights Code | None |
| Crossover | All Ports Blocked |
| Spool Indicator Switch Code | None |
| Seal Material | Buna-N |
| Port T Pressure Rating | 5000 psi |
| AC/DC | AC |
| Valve Type | Standard-Duty |
| Rated Flow [Max] | 175 gal/min |
| Surge Suppressor/Damper | None |
| Model No. | DG5V-8-S-2A-T-M-U-B-10 |
| Pressure [Max] | 5000 psi |
| Electrical Connection | No Connector |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Temperature Range [Max] | 230 °F |
| Port Restrictor Plugs | None |
| Center Position | All Ports Blocked |
| Pilot Pressure Code | None |
| Gauge Port | SAE-4 |
| Housing Code | None |
| Port Restrictor Plug Code | None |
| Manual Override | Plain Override |
| Coil Rating Code | B |
| Pilot Drain Code | T |
| Performance | Standard Performance |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Solenoid Energization Code | None |
| Coil Type | ISO 4400 (Din 43650) Connector |
| Response Type Code | None |
| Electrical Options | None |
| Actuation Identification | Solenoid B |
| Spool Spring Arrangement Code | A |
| Pilot/Drain | External Pilot/Internal Drain |
| Pressure Port Check Valve Pressure | N/A |
| Design No. | 10 |
| Temperature Range [Min] | -40 °F |
| Pressure Port Check Valve Code | None |
| Compatible Fluids | Petroleum Oil |
| Gauge Ports Code | None |
| Mounting | Subplate/Manifold Mount |
| Fluid Cleanliness | 19/17/14 micron |
| Actuator Type | Solenoid |
| Leakage | Standard Performance |
| Reducer Module | No |
| EN Code | None |
| Overrides | Plain Override Solenoid Ends |
| Electrical Options Code | None |
| Pilot Valve Type Code | S |
| Operation | Pilot Operated |
| Response Type | Standard Response |
| Weight | 35.0 LB |