Vickers D08 Solenoid Valve
Item #101907260
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-357131
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Pilot Pressure Code None
Valve Type Standard-Duty
Temperature Range [Min] -40 °F
Center Position P Blocked, A & B to T
Pilot Valve Type Code H
NFPA Size D08
Coil Type ISO 4400 (Din 43650) Connector
Pilot Valve Type CETOP 3, High Performance
Leakage High Performance
Body Material Ductile Iron
AC/DC AC
Indicator Lights No
Operation Pilot Operated
Port Restrictor Plugs None
Pilot/Drain Internal Pilot/Internal Drain
Mechanical Options Adjust Pilot Chokes on Both Ends
Compatible Fluids Petroleum Oil
Gauge Ports Code None
Surge Suppressor/Damper None
Model No. DG5V-8-H-6C-2-T-M-U-B-10
Electrical Options None
Spool Spring Arrangement Code C
Coil Type Code U
Solenoid Energization Code None
Tank Port Rating 5000
Port Restrictor Plug Code None
Actuator Type Solenoid
Seal Material Buna-N
Response Type Standard Response
Spool Code 6
Electrical Connection No Connector
Manual Override Option Code None
Actuation Identification Solenoid A, Solenoid B
Voltage & Frequency 110/120 VAC - 50/60 Hz
Performance High Performance
Solenoid Double
Rated Flow [Max] 175 gal/min
Electrical Options Code None
Electrical Connector Code None
Overrides Plain Override Solenoid Ends
Mounting Subplate/Manifold Mount
Pressure [Max] 5000 psi
Pressure Port Check Valve Code None
Response Type Code None
Temperature Range [Max] 230 °F
Gauge Port SAE-4
Surge Suppressor/Damper Code None
Function 3-Position Spring Centered
Fluid Cleanliness 19/17/14 micron
Coil Rating Code B
Spool Control Modification Code 2
Mechanical Options Code None
Port T Pressure Rating 5000 psi
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Housing Code None
Solenoid Indicator Lights Code None
Reducer Module No
Spool Indicator Switch Code None
EN Code None
Crossover P Blocked, A or B to T
Pilot Drain Code T
Reducer Module Code None
Design No. 10
Manual Override Plain Override
No. of Stages Two Stage
Pressure Port Check Valve Pressure N/A
Weight 35.0 LB