Vickers D03 Solenoid Valve

02-354728

Vickers D03 Solenoid Valve
Item #101974034
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
EN Code None
Housing Code W
Coil Type Code F
Coil Rating Code HL
Spool Spring Arrangement Code B
Solenoid Single
Valve Type High-Performance
Rated Flow [Max] 21 gal/min
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Seal Material Buna-N
Tank Port Rating 3000
Port T Pressure Rating 3000 psi
NFPA Size D03
Reducer Module N/A
Port Restrictor Plugs None
Surge Suppressor/Damper None
Solenoid Indicator Lights Code None
Surge Suppressor/Damper Code None
Manual Override Option Code None
Spool Shift Timing N/A
Solenoid Energization Code None
Operation Solenoid Operated
Electrical Connector Code None
Pressure Port Check Valve Pressure N/A
Pilot Valve Type N/A
Solenoid Code HL
Voltage & Frequency 24 VDC, Low Power Coil
Spool Indicator Switch Code None
Response Type Standard Response
Cycle Rate [Max] N/A
Port T Code 7
Function Code 6
Actuator Type Solenoid
AC/DC DC
Electrical Connection No Connector
Design No. 60
Overrides No Overrides
Function 2-Position Spring Offset, End to Center
Pilot/Drain None
Spool Code 6
Port Restrictor Plug Code None
Crossover P Blocked, A or B to T
Mechanical Options None
Pressure [Max] 5075 psi
Center Position P Blocked, A & B to T
Model No. DG4V 3 6B M FW HL7 60
Indicator Lights No
Electrical Options None
Weight 5.0 LB