Vickers D03 Solenoid Valve

02-354574

Vickers D03 Solenoid Valve
Item #101964437
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Multi-fluid capability without the need to change seals
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
Spool Shift Timing N/A
Spool Code 6
Electrical Connection DIN 43650
Pilot/Drain None
Overrides No Overrides
Temperature Range [Min] -4 °F
Manual Override Plain Override
Performance Standard Performance
Spool Indicator Switch Code None
Coil Rating Code HL
Coil Type Code U
Tank Port Rating 3046
Function Code 6
Manual Override Option Code None
Leakage Standard Performance
Design No. 60
Port T Code 7
AC/DC DC
Seal Material Buna-N
Response Type Standard Response
Operation Solenoid Operated
Electrical Options None
Spool Spring Arrangement Code B
Solenoid Single
NFPA Size D03
Rated Flow [Max] 20 gal/min
Port T Pressure Rating 3000 psi
Crossover P Blocked, A or B to T
Solenoid Code HL
Surge Suppressor/Damper None
Watt Rating 18 W
Function 2-Position Spring Offset, End to Center
Solenoid Energization Code V
Mounting Subplate/Manifold Mount
Valve Type High-Performance
Pilot Valve Type N/A
Body Material Gray Iron
Port Restrictor Plugs None
Solenoid Indicator Lights Code None
Center Position P Blocked, A & B to T
EN Code None
Model No. DG4V-3-6B-VM-U-HL7-60
Surge Suppressor/Damper Code None
Pressure Port Check Valve Pressure N/A
Cycle Rate [Max] N/A
Voltage & Frequency 24 VDC
Electrical Connector Code None
Reducer Module No
Actuator Type Solenoid
Spool Center Condition B Port End
Coil Type ISO 4400 (Din 43650) Connector
Indicator Lights No
Temperature Range [Max] 158 °F
Mechanical Options None
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plug Code None
No. of Stages Single Stage
Compatible Fluids Petroleum Oil
Actuation Identification Solenoid B
Housing Code None
Pressure [Max] 5000 psi
Weight 5.0 LB