Vickers by Danfoss02-354197

02-354197

Vickers D03 Solenoid Valve
Item #101924516
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-354197
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
AC/DC DC
Spool Spring Arrangement Code N
Reducer Module N/A
Housing Code None
Surge Suppressor/Damper None
Crossover All Ports Blocked
Surge Suppressor/Damper Code None
Port T Code 4
Valve Type Standard-Duty
Overrides No Overrides
Model No. DG4V 3S 2N M X2 H4 60
Port Restrictor Plug Code None
Spool Code 2
Design No. 60
Port T Pressure Rating 1000 psi
Function Code 2
Solenoid Indicator Lights Code None
NFPA Size D03
EN Code None
Pressure Port Check Valve Pressure N/A
Operation Solenoid Operated
Tank Port Rating 1000
Seal Material Buna-N
Actuator Type Solenoid
Coil Rating Code H
Response Type Standard Response
Function 3-Position Detented
Indicator Lights No
Cycle Rate [Max] N/A
Voltage & Frequency 24 VDC
Coil Type Code X2
Pressure [Max] 5075 psi
Manual Override Option Code None
Electrical Options None
Port Restrictor Plugs None
Solenoid Code H
Pilot Valve Type N/A
Rated Flow [Max] 10.5 gal/min
Electrical Connection No Connector
Electrical Connector Code None
Center Position All Ports Blocked
Coil Type Hazardous Location Solenoids to Meet UL & CSA Approval
Pilot/Drain None
Spool Shift Timing N/A
Solenoid Energization Code None
Mechanical Options None
Solenoid Double
Spool Indicator Switch Code None
Weight 5.0 LB