Vickers D03 Solenoid Valve

02-354178

Vickers D03 Solenoid Valve
Item #101912989
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Operation Solenoid Operated
Coil Type Code F
Port Restrictor Plugs None
Spool Shift Timing N/A
Seal Material Buna-N
Port Restrictor Plug Code None
Tank Port Rating 3046
Solenoid Code H
Pressure Port Check Valve Pressure N/A
Port T Code 7
NFPA Size D03
EN Code None
Coil Rating Code H
Electrical Connector Code T
Solenoid Indicator Lights Code L
Indicator Lights Yes
No. of Stages Single Stage
Pressure [Max] 5000 psi
Leakage Standard Performance
Body Material Gray Iron
Performance High Performance
Model No. DG4V-3-6A-M-FTWL-H7-60
Design No. 60
AC/DC DC
Mechanical Options None
Response Time 28 to 45 ms
Actuation Identification Solenoid B
Manual Override Plain Override
Fluid Cleanliness 19/17/14 micron
Function 2-Position Spring Offset, End to End
Spool Indicator Switch Code None
Voltage & Frequency 24 VDC
Electrical Options None
Cycle Rate [Max] N/A
Function Code 6
Manual Override Option Code None
Actuator Type Solenoid
Surge Suppressor/Damper Code None
Solenoid Single
Electrical Connection Wired Terminal Block
Compatible Fluids Petroleum Oil
Solenoid Energization Code None
Surge Suppressor/Damper None
Temperature Range [Max] 158 °F
Crossover P Blocked, A or B to T
Overrides No Overrides
Valve Type High-Performance
Center Position P Blocked, A & B to T
Pilot Valve Type N/A
Spool Code 6
Port T Pressure Rating 3000 psi
Temperature Range [Min] -4 °F
Spool Spring Arrangement Code A
Watt Rating 30 W
Pilot/Drain None
Reducer Module No
Mounting Subplate/Manifold Mount
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Rated Flow [Max] 20 gal/min
Housing Code W
Response Type Standard Response
Weight 5.0 LB