Vickers D03 Solenoid Valve

02-350239

Vickers D03 Solenoid Valve
Item #101943142
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Center Position All Ports Open
Function Code 0
Manual Override Option Code None
Port T Code 5
Solenoid Double
Pressure [Max] 5075 psi
EN Code None
Spool Spring Arrangement Code C
Operation Solenoid Operated
Port Restrictor Plugs None
Actuator Type Solenoid
Electrical Connector Code T
Tank Port Rating 1500
Coil Type Code F
Port Restrictor Plug Code None
Electrical Options None
Surge Suppressor/Damper None
Function 3-Position Spring Centered
Pilot/Drain None
Crossover All Ports Open
Model No. DG4V 3S 0C M FTW B5 60
Surge Suppressor/Damper Code None
Spool Shift Timing N/A
Rated Flow [Max] 10.5 gal/min
Design No. 60
Solenoid Energization Code None
Port T Pressure Rating 1500 psi
Pressure Port Check Valve Pressure N/A
Pilot Valve Type N/A
Spool Code 0
Spool Indicator Switch Code None
Valve Type Standard-Duty
Seal Material Buna-N
Cycle Rate [Max] N/A
AC/DC AC
Response Type Standard Response
Mechanical Options None
Solenoid Code B
Voltage & Frequency 110/120 VAC - 50/60 Hz
Indicator Lights No
NFPA Size D03
Electrical Connection Wired Terminal Block
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Solenoid Indicator Lights Code None
Reducer Module N/A
Coil Rating Code B
Housing Code W
Overrides No Overrides
Weight 5.0 LB