Skip to content Skip to navigation menu
Vickers by Danfoss02-344687

02-344687

Vickers D03 Solenoid Valve
Item #102094935
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-344687
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Cycle Rate [Max] N/A
Model No. DG4V-3-2C-M-FW-H7-60-EN21
Fluid Cleanliness 19/17/14 micron
Actuator Type Solenoid
Response Type Standard Response
No. of Stages Single Stage
Manual Override Option Code None
Electrical Connection No Connector
Port T Code 7
Solenoid Code H
Solenoid Double
Tank Port Rating 3046
Surge Suppressor/Damper None
Reducer Module No
Seal Material Buna-N
Pressure Port Check Valve Pressure N/A
NFPA Size D03
Pressure [Max] 5000 psi
Function Code 2
Response Time 28 to 45 ms
Solenoid Energization Code None
Center Position All Ports Blocked
Overrides No Overrides
Pilot/Drain None
Compatible Fluids Petroleum Oil
Watt Rating 30 W
Function 3-Position Spring Centered
Manual Override Plain Override
Spool Shift Timing N/A
Actuation Identification Solenoid A, Solenoid B
Voltage & Frequency 24 VDC
Temperature Range [Min] -4 °F
EN Code EN21
Surge Suppressor/Damper Code None
Leakage Standard Performance
Spool Spring Arrangement Code C
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
AC/DC DC
Valve Type High-Performance
Solenoid Indicator Lights Code None
Coil Rating Code H
Housing Code W
Spool Code 2
Crossover All Ports Blocked
Port Restrictor Plugs None
Design No. 60
Operation Solenoid Operated
Electrical Connector Code None
Rated Flow [Max] 20 gal/min
Mounting Subplate/Manifold Mount
Port T Pressure Rating 3000 psi
Pilot Valve Type N/A
Performance High Performance
Coil Type Code F
Port Restrictor Plug Code None
Mechanical Options None
Electrical Options None
Indicator Lights No
Spool Indicator Switch Code None
Temperature Range [Max] 158 °F
Body Material Gray Iron
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison