Vickers by Danfoss02-343843

02-343843

Vickers D08 Solenoid Valve
Item #102094944
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-343843
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • All conveyor troughs should have some type of cover not only to keep material inside the trough and to protect material in the trough from outside elements, but also as a safety precaution.
Tank Port Rating 5000
Body Material Ductile Iron
Coil Rating Code B
Model No. DG5V-8-S-2N-T-K-M-U-B-10
Surge Suppressor/Damper None
AC/DC AC
Surge Suppressor/Damper Code None
Seal Material Buna-N
Solenoid Indicator Lights Code None
Overrides Plain Override Solenoid Ends
Pilot Pressure Code None
Actuator Type Solenoid
Center Position All Ports Blocked
Spool Spring Arrangement Code N
Coil Type Code U
Reducer Module Code None
Reducer Module No
Gauge Ports Code None
Manual Override Option Code None
Response Type Code None
Pilot Valve Type Code S
Pressure Port Check Valve Code K
Fluid Cleanliness 19/17/14 micron
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Response Type Standard Response
Port T Pressure Rating 5000 psi
Valve Type Standard-Duty
Housing Code None
Gauge Port SAE-4
Electrical Connection No Connector
Coil Type ISO 4400 (Din 43650) Connector
NFPA Size D08
Pressure [Max] 5000 psi
Pilot Drain Code T
No. of Stages Two Stage
EN Code None
Port Restrictor Plug Code None
Solenoid Double
Spool Control Modification Code None
Spool Indicator Switch Code None
Mechanical Options Code None
Function 3-Position Detented
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Code 2
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Min] -40 °F
Pressure Port Check Valve Pressure 5 psi
Pilot/Drain External Pilot/Internal Drain
Solenoid Energization Code None
Design No. 10
Crossover All Ports Blocked
Pilot Valve Type CETOP 3, Standard Performance
Rated Flow [Max] 175 gal/min
Compatible Fluids Petroleum Oil
Mounting Subplate/Manifold Mount
Leakage Standard Performance
Electrical Options Code None
Temperature Range [Max] 230 °F
Performance Standard Performance
Electrical Options None
Operation Pilot Operated
Indicator Lights No
Port Restrictor Plugs None
Manual Override Plain Override
Electrical Connector Code None
Mechanical Options None
Weight 31.87 LB