Vickers by Danfoss02-342570

02-342570

Vickers D08 Solenoid Valve
Item #101908914
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-342570
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Pressure Port Check Valve Code None
Mechanical Options Code None
Reducer Module N/A
Port T Pressure Rating 5000 psi
Port Restrictor Plug Code None
Electrical Connection Wired Terminal Block
Manual Override Option Code None
Pilot/Drain Internal Pilot/Internal Drain
Spool Control Modification Code None
Surge Suppressor/Damper None
Coil Rating Code B
Mechanical Options None
Pilot Valve Type Code S
Function 3-Position Spring Centered
Electrical Options Code None
Center Position P Blocked, A & B to T
Spool Spring Arrangement Code C
Port Restrictor Plugs None
Pressure [Max] 5000 psi
Spool Indicator Switch Code None
Response Type Code None
Seal Material Buna-N
Electrical Connector Code T
Solenoid Indicator Lights Code L
Pilot Drain Code T
Overrides Plain Override Solenoid Ends
Housing Code W
Model No. DG5V-8-S-33C-T-M-FTWL-B-10
Rated Flow [Max] 185 gal/min
Solenoid Energization Code None
Manual Override Plain Override
NFPA Size D08
Surge Suppressor/Damper Code None
Operation Pilot Operated
Gauge Ports Code None
Crossover P Blocked, A or B to T
Response Type Standard Response
Pressure Port Check Valve Pressure N/A
Design No. 10
Solenoid Double
Reducer Module Code None
Pilot Pressure Code None
Indicator Lights Yes
AC/DC AC
Pilot Valve Type CETOP 3, Standard Performance
EN Code None
Gauge Port SAE-4
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Code 33
Actuator Type Solenoid
Tank Port Rating 5000
Coil Type Code F
Electrical Options None
Valve Type Standard-Duty
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Weight 35.0 LB