Vickers by Danfoss02-342145

02-342145

DG5V-10 Series Pilot Operated Directional Valve
Item #101908840
  • Double Sol Pilot Operated Directional Valve
  • 3-Pos Spring Centered
  • 110/120 VAC - 50/60 Hz
  • Flying Leads, 1/2 NPT Thread Wiring Hsg
  • No Connector
  • Ctr Pos: P to T, A & B Blocked
  • Ext Pilot / Ext Drain
  • None
  • Pilot Valve: CETOP 3, High Performance
+ Show More + Show Less
Vickers by Danfoss02-342145
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Double Sol Pilot Operated Directional Valve
  • 3-Pos Spring Centered
  • 110/120 VAC - 50/60 Hz
  • Flying Leads, 1/2 NPT Thread Wiring Hsg
  • No Connector

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Pilot Pressure Code E
Crossover All Ports Open, Restricted
Pressure [Max] 5000 psi
Mechanical Options None
Pilot Valve Type CETOP 3, High Performance
Operation Pilot Operated
Coil Type Code F
Response Type Code None
Valve Type Standard-Duty
Reducer Module N/A
Seal Material Buna-N
Pressure Port Check Valve Code None
Solenoid Indicator Lights Code None
NFPA Size D10
Gauge Port SAE-4
Pressure Port Check Valve Pressure N/A
Design No. 10
Coil Type Flying Leads, 1/2 NPT Thread Wiring Housing
Coil Rating Code B
Pilot Valve Type Code H
Electrical Options None
Manual Override Option Code None
Surge Suppressor/Damper None
Port T Pressure Rating 3000 psi
Pilot Drain Code None
Port Restrictor Plugs None
Gauge Ports Code None
Pilot Pressure [Max] 3000 psi
Pilot/Drain External Pilot/External Drain
Surge Suppressor/Damper Code None
Spool Spring Arrangement Code C
Solenoid Double
Electrical Connector Code None
Reducer Module Code None
Spool Code 8
Indicator Lights No
Solenoid Energization Code V
Assembly Code None
Voltage & Frequency 110/120 VAC – 50/60 Hz
Actuator Type Solenoid
Electrical Connection No Connector
Port Restrictor Plug Code None
Center Position P to T, A & B Blocked
AC/DC AC
Electrical Options Code None
EN Code EN503
Rated Flow [Max] 290 gal/min
Housing Code W
Spool Control Modification Code None
Function 3-Position Spring Centered
Overrides Plain Override Solenoid Ends
Response Type Standard Response
Weight 100.0 LB