Vickers by Danfoss02-342106

02-342106

Vickers D08 Solenoid Valve
Item #101909098
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-342106
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Surge Suppressor/Damper Code None
Port T Pressure Rating 5000 psi
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Pilot Drain Code None
Manual Override Option Code None
Function 3-Position Spring Centered
Solenoid Energization Code V
Housing Code W
Port Restrictor Plugs None
Reducer Module Code None
Tank Port Rating 5000
Operation Pilot Operated
Electrical Connection No Connector
Fluid Cleanliness 19/17/14 micron
Body Material Gray Iron
Center Position P to T, A & B Blocked
Design No. 10
Seal Material Buna-N
Coil Rating Code B
Pilot Valve Type Code H
Pressure Port Check Valve Code None
Response Type Standard Response
Spool Indicator Switch Code None
Gauge Port SAE-4
Pilot/Drain External Pilot/Internal Drain
Compatible Fluids Petroleum Oil
Performance High Performance
Spool Spring Arrangement Code C
Pilot Pressure Code E
Pressure Port Check Valve Pressure N/A
Mounting Subplate/Manifold Mount
Solenoid Double
Electrical Options None
Pressure [Max] 5000 psi
Gauge Ports Code None
Coil Type Code F
EN Code None
Response Type Code None
Actuator Type Solenoid
Leakage Standard Performance
Indicator Lights No
Voltage & Frequency 110/120 VAC - 50/60 Hz
NFPA Size D08
Reducer Module No
Mechanical Options None
Pilot Valve Type CETOP 3, High Performance
Mechanical Options Code None
Electrical Connector Code None
No. of Stages Two Stage
Spool Code 8
Valve Type Standard-Duty
Model No. DG5V-8-H-8C-E-VM-FW-B-10
Manual Override Plain Override
Spool Center Condition A Port and Double Offset sensing switch on B Port
Port Restrictor Plug Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
AC/DC AC
Spool Control Modification Code None
Overrides Plain Override Solenoid Ends
Rated Flow [Max] 175 gal/min
Solenoid Indicator Lights Code None
Crossover All Ports Open, Restricted
Surge Suppressor/Damper None
Electrical Options Code None
Weight 35.0 LB