Vickers by Danfoss02-339249

02-339249

Vickers D08 Solenoid Valve
Item #102154287
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-339249
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Buna-N is not recommended for use with CIP Sanitizing Agent OXONIA – use EPDM or silicone
Mechanical Options Code None
Electrical Options None
Port T Pressure Rating 5000 psi
Spool Spring Arrangement Code N
Electrical Connection No Connector
Mechanical Options None
AC/DC AC
Design No. 10
Center Position All Ports Blocked
Actuator Type Solenoid
Seal Material Buna-N
Reducer Module N/A
Pressure [Max] 5000 psi
Manual Override Option Code None
Coil Rating Code B
Solenoid Energization Code None
Gauge Port SAE-4
Overrides Plain Override Solenoid Ends
Port Restrictor Plugs None
Coil Type Code U
Solenoid Double
Pressure Port Check Valve Pressure N/A
Reducer Module Code None
Indicator Lights No
Manual Override Plain Override
Crossover All Ports Blocked
Spool Control Modification Code None
Solenoid Indicator Lights Code None
Pilot/Drain External Pilot/Internal Drain
NFPA Size D08
Spool Code 2
Pilot Drain Code None
Port Restrictor Plug Code None
Valve Type Standard-Duty
Spool Indicator Switch Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Function 3-Position Detented
EN Code None
Pressure Port Check Valve Code None
Housing Code None
Pilot Pressure Code None
Response Type Standard Response
Electrical Options Code None
Response Type Code None
Surge Suppressor/Damper None
Electrical Connector Code None
Rated Flow [Max] 185 gal/min
Operation Pilot Operated
Model No. DG5V-8-S-2N-M-U-B-10
Pilot Valve Type Code S
Pilot Valve Type CETOP 3, Standard Performance
Surge Suppressor/Damper Code None
Tank Port Rating 5000
Coil Type DIN 43650
Gauge Ports Code None
Weight 35.0 LB