Vickers by Danfoss02-339127

02-339127

Vickers D08 Solenoid Valve
Item #102171327
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-339127
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Pilot Drain Code None
Pressure [Max] 5000 psi
Model No. DG5V-8-S-6C-2-M-FW-B-10
Manual Override Option Code None
NFPA Size D08
Mechanical Options Code None
Electrical Connector Code None
Gauge Port SAE-4
Electrical Options None
Spool Indicator Switch Code None
Coil Type Code F
Response Type Standard Response
Housing Code W
Spool Control Modification Code 2
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Overrides Plain Override Solenoid Ends
Actuator Type Solenoid
Seal Material Buna-N
Solenoid Indicator Lights Code None
Gauge Ports Code None
Pressure Port Check Valve Pressure N/A
Port Restrictor Plugs None
Spool Spring Arrangement Code C
Pressure Port Check Valve Code None
Port T Pressure Rating 5000 psi
Valve Type Standard-Duty
Response Type Code None
Center Position P Blocked, A & B to T
Spool Code 6
Surge Suppressor/Damper Code None
Operation Pilot Operated
Manual Override Plain Override
Port Restrictor Plug Code None
Pilot Pressure Code None
Pilot Valve Type Code S
Reducer Module N/A
Electrical Options Code None
Pilot Valve Type CETOP 3, Standard Performance
Solenoid Energization Code None
Pilot/Drain External Pilot/Internal Drain
Crossover P Blocked, A or B to T
EN Code None
Solenoid Double
Surge Suppressor/Damper None
Mechanical Options Adjust Pilot Chokes on Both Ends
Function 3-Position Spring Centered
Reducer Module Code None
AC/DC AC
Coil Rating Code B
Voltage & Frequency 110/120 VAC - 50/60 Hz
Rated Flow [Max] 185 gal/min
Design No. 10
Electrical Connection No Connector
Indicator Lights No
Tank Port Rating 5000
Weight 35.0 LB