Vickers by Danfoss02-338242

02-338242

Vickers D08 Solenoid Valve
Item #102155928
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-338242
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Because timing belts have an inherent, gentle side thrust, it is necessary to use at least one flanged pulley to prevent the belt from riding off
Seal Material Buna-N
Electrical Options None
Surge Suppressor/Damper None
Electrical Options Code None
Coil Type Code U
Reducer Module No
NFPA Size D08
Gauge Port SAE-4
Reducer Module Code None
Coil Rating Code H
Port T Pressure Rating 5000 psi
Surge Suppressor/Damper Code None
Temperature Range [Min] -40 °F
Spool Control Modification Code None
Mounting Subplate/Manifold Mount
Leakage High Performance
Center Position All Ports Blocked
Body Material Ductile Iron
Performance High Performance
Spool Code 2
Compatible Fluids Petroleum Oil
Manual Override Plain Override
Spool Spring Arrangement Code C
Pilot/Drain External Pilot/Internal Drain
Port Restrictor Plugs None
Solenoid Energization Code None
Pressure Port Check Valve Code None
Actuation Identification Solenoid A, Solenoid B
No. of Stages Two Stage
Solenoid Indicator Lights Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Rated Flow [Max] 175 gal/min
Overrides Plain Override Solenoid Ends
Actuator Type Solenoid
Pilot Valve Type CETOP 3, High Performance
Response Type Standard Response
Port Restrictor Plug Code None
Temperature Range [Max] 230 °F
Gauge Ports Code None
Spool Indicator Switch Code None
Fluid Cleanliness 19/17/14 micron
Crossover All Ports Blocked
Electrical Connector Code None
Design No. 10
EN Code None
Indicator Lights No
Voltage & Frequency 24 VDC
Response Type Code None
Valve Type Standard-Duty
Pilot Drain Code None
Solenoid Double
Electrical Connection No Connector
Manual Override Option Code None
Operation Pilot Operated
Model No. DG5V-8-H-2C-M-U-H-10
Pilot Pressure Code None
Housing Code None
Tank Port Rating 5000
Pressure Port Check Valve Pressure N/A
Pressure [Max] 5000 psi
Coil Type ISO 4400 (Din 43650) Connector
AC/DC DC
Mechanical Options None
Pilot Valve Type Code H
Function 3-Position Spring Centered
Mechanical Options Code None
Watt Rating 30 W
Weight 35.0 LB