Vickers by Danfoss02-338240

02-338240

Vickers D08 Solenoid Valve
Item #102172654
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-338240
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Should not be exposed to ketones, chlorinated hydrocarbons and esters found in lacquer thinners, degreasers, paint strippers, etc., which may cause the backing to swell or curl
Gauge Port SAE-4
Pressure Port Check Valve Pressure N/A
Electrical Options Code None
Pilot Valve Type Code S
Surge Suppressor/Damper Code None
Valve Type Standard-Duty
Spool Spring Arrangement Code C
AC/DC AC
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Design No. 10
Port T Pressure Rating 5000 psi
Center Position P & B Blocked, A to T
Temperature Range [Max] 230 °F
Mechanical Options None
Actuator Type Solenoid
Model No. DG5V-8-S-3C-M-FTWL-B-10
Electrical Options None
Reducer Module No
Actuation Identification Solenoid A, Solenoid B
Indicator Lights Yes
Mechanical Options Code None
Manual Override Option Code None
Mounting Subplate/Manifold Mount
Port Restrictor Plugs None
Seal Material Buna-N
Compatible Fluids Petroleum Oil
Function 3-Position Spring Centered
Solenoid Double
Voltage & Frequency 110/120 VAC - 50/60 Hz
Leakage Standard Performance
Housing Code W
Overrides Plain Override Solenoid Ends
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Response Type Standard Response
Manual Override Plain Override
EN Code None
Spool Control Modification Code None
Spool Code 3
Surge Suppressor/Damper None
Pressure [Max] 5000 psi
Solenoid Energization Code None
Operation Pilot Operated
Rated Flow [Max] 175 gal/min
Electrical Connection Wired Terminal Block
Port Restrictor Plug Code None
Body Material Ductile Iron
Fluid Cleanliness 19/17/14 micron
Pilot/Drain Internal Pilot/External Drain
Pilot Valve Type CETOP 3, Standard Performance
Coil Rating Code B
Temperature Range [Min] -40 °F
Response Type Code None
Tank Port Rating 5000
Pilot Pressure Code None
Pressure Port Check Valve Code None
Crossover All Ports Blocked, or P & B Blocked, A to T
No. of Stages Two Stage
Coil Type Code F
Solenoid Indicator Lights Code L
NFPA Size D08
Pilot Drain Code None
Electrical Connector Code T
Spool Indicator Switch Code None
Performance Standard Performance
Gauge Ports Code None
Reducer Module Code None
Weight 35.0 LB