Vickers D10 Solenoid Valve
Item #102220550
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-337563
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Pilot Drain Code None
Gauge Port SAE-4
Coil Type No Coil
Surge Suppressor/Damper Code None
Reducer Module N/A
Overrides None
Pilot Valve Type CETOP 5, Wet Armature
Pressure Port Check Valve Pressure N/A
Pilot/Drain External Drain
Solenoid Energization Code None
Function 2-Position Spring Offset
Spool Spring Arrangement Code A
Operation Solenoid Operated
Spool Code 2
Pilot Pressure [Max] 3000 psi
Seal Material Buna-N
EN Code None
Pressure Port Check Valve Code None
Reducer Module Code None
Crossover All Ports Blocked
Fluid Cleanliness 19/17/14 micron
Rated Flow [Max] 175 gal/min
Coil Type Code None
Tank Port Rating 3000
Port T Pressure Rating 3000 psi
Temperature Range [Max] 150.8 °F
Assembly Code None
Mounting Subplate/Manifold Mount
No. of Stages Two Stage
Design No. 10
Pilot Valve Type Code W
Compatible Fluids Petroleum Oil
Manual Override Plain Override
Center Position All Ports Blocked
Model No. DG5V-10-W-2A-E-M-PA5WL-B-10
Solenoid Indicator Lights Code L
Gauge Ports Code None
Actuator Type Solenoid
AC/DC AC
Voltage & Frequency 110/120 VAC - 50/60 Hz
Electrical Options None
Electrical Connection Five Pin Connector
Indicator Lights Yes
Surge Suppressor/Damper None
Coil Rating Code B
Electrical Options Code None
Port Restrictor Plugs None
Port Restrictor Plug Code None
Valve Type Standard-Duty
Pilot Pressure Code E
Manual Override Option Code None
Body Material Ductile Iron
Solenoid Single
Temperature Range [Min] -0.4 °F
Mechanical Options None
Actuation Identification Solenoid B
Spool Control Modification Code None
Response Type Code None
Leakage Standard Performance
Housing Code W
Electrical Connector Code PA5
Pressure [Max] 5000 psi
NFPA Size D10
Response Type Standard Response
Weight 100.0 LB