Vickers by Danfoss02-337168

02-337168

Vickers D08 Solenoid Valve
Item #101975622
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337168
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Spool Spring Arrangement Code C
Response Type Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Mounting Subplate/Manifold Mount
Pilot Pressure Code None
Pressure [Max] 5000 psi
Solenoid Energization Code V
Function 3-Position Spring Centered
Port Restrictor Plugs None
No. of Stages Two Stage
NFPA Size D08
Coil Rating Code B
Solenoid Indicator Lights Code None
Pilot/Drain Internal Pilot/External Drain
Design No. 10
Compatible Fluids Petroleum Oil
Pilot Valve Type Code S
Reducer Module No
Model No. DG5V-8-S-8C-2-VM-FW-B-10
Spool Code 8
Housing Code W
Fluid Cleanliness 19/17/14 micron
Temperature Range [Min] -40 °F
Performance Standard Performance
Gauge Port SAE-4
Surge Suppressor/Damper Code None
Port Restrictor Plug Code None
Temperature Range [Max] 230 °F
Overrides Plain Override Solenoid Ends
Electrical Connection No Connector
Pilot Drain Code None
Spool Control Modification Code 2
Mechanical Options Adjust Pilot Chokes on Both Ends
Voltage & Frequency 110/120 VAC - 50/60 Hz
Center Position P to T, A & B Blocked
Manual Override Option Code None
Coil Type Code F
Seal Material Buna-N
Tank Port Rating 5000
EN Code None
Operation Pilot Operated
Gauge Ports Code None
Valve Type Standard-Duty
Surge Suppressor/Damper None
Electrical Connector Code None
Pilot Valve Type CETOP 3, Standard Performance
Solenoid Double
Pressure Port Check Valve Pressure N/A
Spool Indicator Switch Code None
Electrical Options Code None
Pressure Port Check Valve Code None
Manual Override Plain Override
Actuation Identification Solenoid A, Solenoid B
Indicator Lights No
Port T Pressure Rating 5000 psi
Response Type Standard Response
Mechanical Options Code None
Reducer Module Code None
Rated Flow [Max] 175 gal/min
Leakage Standard Performance
Actuator Type Solenoid
AC/DC AC
Body Material Ductile Iron
Electrical Options None
Crossover All Ports Open, Restricted
Weight 35.0 LB