Vickers by Danfoss02-336845

02-336845

Vickers D08 Solenoid Valve
Item #101949865
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-336845
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Gauge Port SAE-4
Port Restrictor Plugs None
Coil Type Code U
Pressure Port Check Valve Pressure N/A
Spool Indicator Switch Code None
Reducer Module Code None
Port T Pressure Rating 5000 psi
Electrical Connector Code None
Operation Pilot Operated
Electrical Connection No Connector
Pilot Valve Type Code H
Valve Type Standard-Duty
Coil Type DIN 43650
Electrical Options Code None
Pilot Pressure Code None
Voltage & Frequency 110 VAC - 50 Hz
Tank Port Rating 5000
Pressure Port Check Valve Code None
Port Restrictor Plug Code None
Manual Override Option Code None
Overrides Plain Override Solenoid Ends
NFPA Size D08
Design No. 10
Spool Control Modification Code None
EN Code None
Crossover All Ports Blocked, or P & B Blocked, A to T
Spool Code 3
Spool Spring Arrangement Code C
Coil Rating Code A
Pilot/Drain External Pilot/Internal Drain
Indicator Lights No
Housing Code None
Reducer Module N/A
Function 3-Position Spring Centered
Center Position P & B Blocked, A to T
Seal Material Buna-N
Pilot Valve Type CETOP 3, High Performance
Surge Suppressor/Damper None
Pressure [Max] 5000 psi
Actuator Type Solenoid
AC/DC AC
Surge Suppressor/Damper Code None
Response Type Standard Response
Mechanical Options Code None
Mechanical Options None
Rated Flow [Max] 185 gal/min
Manual Override Plain Override
Pilot Drain Code T
Electrical Options None
Solenoid Indicator Lights Code None
Gauge Ports Code None
Solenoid Energization Code None
Response Type Code None
Solenoid Double
Model No. DG5V-8-H-3C-T-M-U-A-10
Weight 35.0 LB