Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-336476

Vickers D03 Solenoid Valve
Item #101949868
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function

description

  • For directing and stopping flow at any point in a hydraulic system. Its primary function is to determine the direction of fluid flow in a work cylinder or control the direction of rotation of a fluid motor. Port connections are made by mounting the valve on a subplate or manifold. The valve has wet armature type solenoids. It is derived from the standard model series DG4V-3S-60.

features

  • High reliability
  • Scratch-proof override seals
  • Multiple electrical connections
  • Minimal pressure drop
  • High thermal shock and impact resistance due to new coil design
  • Tank line can withstand pressures up to 210 bar (3,000 psi)

compliances

  • 0
Actuation Identification Solenoid A
Electrical Connection DIN 43650
Indicator Lights No
Pilot/Drain None
Tank Port Rating 1450
Pilot Valve Type N/A
Body Material Gray Iron
Performance Standard Performance
Port Restrictor Plug Code None
Leakage Standard Performance
Pressure [Max] 5000 psi
Overrides No Overrides
Valve Type Standard-Duty for Mobile Equipment
Manual Override Option Code None
Spool Spring Arrangement Code A
Temperature Range [Min] -4 °F
Mechanical Options None
Solenoid Code H
Voltage & Frequency 24 VDC
Mounting Subplate/Manifold Mount
Manual Override Plain Override
Spool Indicator Switch Code None
Center Position All Ports Blocked
Design No. 60
Operation Solenoid Operated
Electrical Options None
Port Restrictor Plugs None
Response Time 40 to 60 ms
Cycle Rate [Max] N/A
Pressure Port Check Valve Pressure N/A
Coil Type Code U
Port T Code 7
Rated Flow [Max] 10 gal/min
Coil Type ISO 4400
Watt Rating 30 W
Solenoid Energization Code None
Coil Rating Code H
Solenoid Indicator Lights Code None
No. of Stages Single Stage
Function 2-Position Spring Offset, Left Hand Build
Crossover All Ports Blocked
Compatible Fluids Petroleum Oil
EN Code EN490
Temperature Range [Max] 158 °F
Spool Shift Timing N/A
Housing Code None
Surge Suppressor/Damper None
Model No. DG4V-3S-2AL-M-U-H7-60-EN490
NFPA Size D03
Reducer Module No
Actuator Type Solenoid
Function Code 2
Spool Code 2
Electrical Connector Code None
Port T Pressure Rating 3000 psi
Response Type Standard Response
AC/DC DC
Fluid Cleanliness 19/17/14 micron
Solenoid Single
Surge Suppressor/Damper Code None
Seal Material Buna-N
Weight 5.0 LB