Vickers D10 Solenoid Valve

02-336067

Vickers D10 Solenoid Valve
Item #101975627
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers D10 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Port Restrictor Plug Code None
Valve Type Standard-Duty
Overrides Plain Override Solenoid Ends
Tank Port Rating 3000
Electrical Connection No Connector
Spool Spring Arrangement Code A
Pilot/Drain External Pilot/Internal Drain
Manual Override Plain Override
Solenoid Single
Pilot Valve Type Code S
Electrical Options Code None
Gauge Ports Code None
Electrical Connector Code None
Operation Pilot Operated
Actuator Type Solenoid
Seal Material Buna-N
Surge Suppressor/Damper Code None
Port Restrictor Plugs None
Center Position All Ports Blocked
Housing Code None
Manual Override Option Code None
Electrical Options None
Pilot Pressure [Max] 3000 psi
Function 2-Position Spring Offset
Reducer Module N/A
Coil Rating Code D
Reducer Module Code None
Response Type Code None
Voltage & Frequency 220/240 VAC - 50/60 Hz
Coil Type Code U
Spool Control Modification Code 2
Pilot Valve Type CETOP 3, Standard Performance
Solenoid Energization Code None
Response Type Standard Response
Pilot Drain Code None
Assembly Code None
Mechanical Options Adjust Pilot Chokes on Both Ends
Pilot Pressure Code E
Gauge Port SAE-4
Port T Pressure Rating 3000 psi
EN Code None
Indicator Lights No
Crossover All Ports Blocked
Spool Code 2
Coil Type DIN 43650
AC/DC AC
Pressure Port Check Valve Pressure N/A
Pressure Port Check Valve Code None
Surge Suppressor/Damper None
Pressure [Max] 5000 psi
Rated Flow [Max] 290 gal/min
Model No. DG5V-10-S-2A-2-E-M-U-D-10
Design No. 10
Solenoid Indicator Lights Code None
NFPA Size D10
Weight 100.0 LB
We're here for you
with Service Centers across the country -
We have your back