Vickers by Danfoss02-333915

02-333915

DG4V-3S Series Solenoid Operated Directional Valve
Item #101977975
  • Single Solenoid Valve
  • Standard-Duty
  • D03
  • 2-Pos Spring Offset, End to End
  • 24 VDC
  • Wired Terminal Block
  • 1/2 NPT Conduit Box, 1/2 NPT Thread Wiring Housing
  • Center Pos: APB
  • Crossover: APB
  • w/Lights
  • 10.50 gpm Max Flow
+ Show More + Show Less
Vickers by Danfoss02-333915
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Single Solenoid Valve
  • Standard-Duty
  • D03
  • 2-Pos Spring Offset, End to End
  • 24 VDC

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
AC/DC DC
Pilot/Drain None
Surge Suppressor/Damper None
Solenoid Indicator Lights Code L
Function Code 2
Mechanical Options None
Electrical Connection Wired Terminal Block
Reducer Module N/A
Manual Override Option Code Z
Port T Pressure Rating 1500 psi
Spool Indicator Switch Code None
Electrical Connector Code T
Solenoid Single
Electrical Options None
Spool Code 2
Overrides No Overrides
Indicator Lights Yes
Rated Flow [Max] 10.5 gal/min
Pilot Valve Type N/A
Coil Type Code F
Crossover All Ports Blocked
Design No. 60
Valve Type Standard-Duty
Voltage & Frequency 24 VDC
Housing Code W
EN Code None
NFPA Size D03
Response Type Standard Response
Solenoid Code H
Actuator Type Solenoid
Pressure [Max] 5075 psi
Solenoid Energization Code None
Spool Shift Timing N/A
Coil Rating Code H
Spool Spring Arrangement Code A
Surge Suppressor/Damper Code None
Coil Type Flying Leads, 1/2 NPT Thread Wiring Housing
Port T Code 5
Center Position All Ports Blocked
Cycle Rate [Max] N/A
Seal Material Buna-N
Port Restrictor Plug Code None
Pressure Port Check Valve Pressure N/A
Operation Solenoid Operated
Function 2-Position Spring Offset, End to End
Port Restrictor Plugs None
Weight 5.0 LB