Vickers by Danfoss02-330477

02-330477

Vickers D08 Solenoid Valve
Item #101966441
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-330477
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • If the drive has more than three pulleys, every other pulley should be flanged
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Gauge Ports Code None
Design No. 10
Model No. DG5V-8-H-3C-M-FW-B-10
Operation Pilot Operated
Manual Override Plain Override
Port Restrictor Plug Code None
Body Material Ductile Iron
Compatible Fluids Petroleum Oil
Surge Suppressor/Damper None
Coil Type Code F
Port T Pressure Rating 5000 psi
Leakage High Performance
Spool Code 3
Electrical Options Code None
Pressure Port Check Valve Code None
Temperature Range [Min] -40 °F
NFPA Size D08
Indicator Lights No
Mounting Subplate/Manifold Mount
Actuation Identification Solenoid A, Solenoid B
Function 3-Position Spring Centered
Gauge Port SAE-4
Electrical Connector Code None
AC/DC AC
Overrides Plain Override Solenoid Ends
Port Restrictor Plugs None
EN Code None
Manual Override Option Code None
Coil Rating Code B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Response Type Standard Response
Solenoid Energization Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure [Max] 5000 psi
Reducer Module Code None
Pressure Port Check Valve Pressure N/A
Pilot Drain Code None
Surge Suppressor/Damper Code None
Electrical Options None
Mechanical Options None
Tank Port Rating 5000
Response Type Code None
Spool Indicator Switch Code None
Rated Flow [Max] 175 gal/min
Valve Type Standard-Duty
Electrical Connection No Connector
Center Position P & B Blocked, A to T
Pilot Valve Type Code H
Actuator Type Solenoid
Housing Code W
Reducer Module No
Spool Spring Arrangement Code C
Seal Material Buna-N
No. of Stages Two Stage
Pilot Pressure Code None
Performance High Performance
Pilot Valve Type CETOP 3, High Performance
Fluid Cleanliness 19/17/14 micron
Solenoid Double
Spool Control Modification Code None
Crossover All Ports Blocked, or P & B Blocked, A to T
Solenoid Indicator Lights Code None
Mechanical Options Code None
Pilot/Drain Internal Pilot/External Drain
Temperature Range [Max] 230 °F
Weight 35.0 LB