Vickers by Danfoss02-330411

02-330411

Vickers D08 Solenoid Valve
Item #101974360
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers by Danfoss02-330411
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • The DG5S8 are two-stage directional valves with an integrally-mounted DG4V3S pilot valve. These valves are used to control the direction of flow in hydraulic circuits.

compliances

  • 0

caution

  • When cylinders are used with maintenance set attachments or components, the maximum system pressure must be limited to half the rated pressure, which is 5,000 psi
Port Restrictor Plugs None
Spool Center Condition A Port and Double Offset sensing switch on B Port
Actuator Type Solenoid
Center Position P Blocked, A & B to T
Pilot Pressure Code None
Electrical Connection Wired Terminal Block
Body Material Ductile Iron
Temperature Range [Min] -40 °F
Spool Code 6
Coil Rating Code B
Spool Spring Arrangement Code C
Seal Material Buna-N
Crossover P Blocked, A or B to T
Electrical Connector Code T
Response Type Standard Response
Coil Type Code F
Pressure Port Check Valve Code None
Model No. DG5V-8-H-6C-T-M-FTWL-B-10
EN Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Reducer Module Code None
Surge Suppressor/Damper Code None
Pilot/Drain External Pilot/Internal Drain
Housing Code W
Manual Override Plain Override
Electrical Options Code None
Pressure [Max] 5000 psi
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pilot Valve Type CETOP 3, High Performance
Solenoid Energization Code None
Surge Suppressor/Damper None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Gauge Ports Code None
Valve Type Standard-Duty
Spool Indicator Switch Code None
Mechanical Options None
Solenoid Double
Performance High Performance
Pressure Port Check Valve Pressure N/A
Function 3-Position, 4-Way, Spring Centered
Indicator Lights Yes
Operation Pilot Operated
Spool Control Modification Code None
No. of Stages Two Stage
Port T Pressure Rating 5000 psi
Design No. 10
Port Restrictor Plug Code None
Fluid Cleanliness 19/17/14 micron
Electrical Options None
AC/DC AC
Manual Override Option Code None
Compatible Fluids Petroleum Oil
Mechanical Options Code None
Tank Port Rating 5000
Rated Flow [Max] 175 gal/min
Pilot Valve Type Code H
Temperature Range [Max] 230 °F
Pilot Drain Code T
Solenoid Indicator Lights Code L
Overrides Plain Override Solenoid Ends
Response Type Code None
Reducer Module No
Mounting Subplate/Manifold Mount
Gauge Port SAE-4
NFPA Size D08
Leakage High Performance
Actuation Identification Solenoid A, Solenoid B
Weight 35.0 LB