Vickers D08 Solenoid Valve
Item #101974360
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers by Danfoss02-330411
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • The DG5S8 are two-stage directional valves with an integrally-mounted DG4V3S pilot valve. These valves are used to control the direction of flow in hydraulic circuits.

compliances

  • 0

caution

  • When cylinders are used with maintenance set attachments or components, the maximum system pressure must be limited to half the rated pressure, which is 5,000 psi
Pressure Port Check Valve Code None
Port Restrictor Plugs None
Manual Override Option Code None
Gauge Port SAE-4
Temperature Range [Min] -40 °F
Response Type Standard Response
Spool Spring Arrangement Code C
Port Restrictor Plug Code None
Leakage High Performance
Overrides Plain Override Solenoid Ends
Pilot Valve Type CETOP 3, High Performance
Surge Suppressor/Damper Code None
Body Material Ductile Iron
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Actuation Identification Solenoid A, Solenoid B
Model No. DG5V-8-H-6C-T-M-FTWL-B-10
Coil Rating Code B
Actuator Type Solenoid
Manual Override Plain Override
Reducer Module No
Spool Center Condition A Port and Double Offset sensing switch on B Port
Pilot Pressure Code None
Valve Type Standard-Duty
Housing Code W
Fluid Cleanliness 19/17/14 micron
Design No. 10
Gauge Ports Code None
Pilot Drain Code T
No. of Stages Two Stage
Pilot Valve Type Code H
Electrical Connection Wired Terminal Block
Mechanical Options None
Operation Pilot Operated
Pilot/Drain External Pilot/Internal Drain
Mechanical Options Code None
Rated Flow [Max] 175 gal/min
Pressure Port Check Valve Pressure N/A
Port T Pressure Rating 5000 psi
Response Type Code None
Indicator Lights Yes
Crossover P Blocked, A or B to T
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Temperature Range [Max] 230 °F
Pressure [Max] 5000 psi
Spool Code 6
Solenoid Double
Seal Material Buna-N
NFPA Size D08
Mounting Subplate/Manifold Mount
Electrical Options Code None
Performance High Performance
Reducer Module Code None
Solenoid Energization Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Type Code F
Electrical Options None
AC/DC AC
Compatible Fluids Petroleum Oil
Function 3-Position, 4-Way, Spring Centered
Solenoid Indicator Lights Code L
Spool Control Modification Code None
EN Code None
Spool Indicator Switch Code None
Surge Suppressor/Damper None
Center Position P Blocked, A & B to T
Electrical Connector Code T
Tank Port Rating 5000
Weight 35.0 LB