Vickers by Danfoss02-329283

02-329283

Vickers D08 Solenoid Valve
Item #101977676
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-329283
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Maintain 5 to 8 Nm (4 to 6 ft lb) maximum torque on valve tube nut
  • over-tightening may cause failure
Overrides Plain Override Solenoid Ends
Crossover All Ports Open
Pilot Valve Type Code S
Function 2-Position Spring Offset
Seal Material Buna-N
NFPA Size D08
Pilot/Drain External Pilot/Internal Drain
Operation Pilot Operated
Port T Pressure Rating 5000 psi
Pressure [Max] 5000 psi
Gauge Port SAE-4
Spool Indicator Switch Code None
Electrical Connector Code None
AC/DC AC
Surge Suppressor/Damper None
Electrical Options None
Coil Type Code F
Gauge Ports Code None
EN Code None
Port Restrictor Plug Code None
Surge Suppressor/Damper Code None
Response Type Code None
Pilot Pressure Code None
Mechanical Options Code None
Reducer Module Code None
Pressure Port Check Valve Pressure N/A
Housing Code W
Model No. DG5V-8-S-9A-M-FW-B-10
Spool Code 9
Valve Type Standard-Duty
Tank Port Rating 5000
Solenoid Indicator Lights Code None
Spool Spring Arrangement Code A
Mechanical Options None
Design No. 10
Voltage & Frequency 110/120 VAC - 50/60 Hz
Manual Override Plain Override
Pilot Drain Code None
Actuator Type Solenoid
Coil Rating Code B
Manual Override Option Code None
Indicator Lights No
Electrical Connection No Connector
Reducer Module N/A
Rated Flow [Max] 185 gal/min
Electrical Options Code None
Solenoid Single
Pilot Valve Type CETOP 3, Standard Performance
Response Type Standard Response
Center Position All Ports Open Over Tapers
Port Restrictor Plugs None
Pressure Port Check Valve Code None
Spool Control Modification Code None
Solenoid Energization Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Weight 35.0 LB