Vickers D08 Solenoid Valve
Item #101975663
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329274
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Grease pockets must be filled with a suitable lubricant before assembly.
Performance Standard Performance
Electrical Connector Code None
Reducer Module No
Port T Pressure Rating 5000 psi
Electrical Options None
Model No. DG5V-8-S-8C-E-VM-U-D-10
Voltage & Frequency 220/240 VAC - 50/60 Hz
Coil Rating Code D
Function 3-Position Spring Centered
Leakage Standard Performance
Spool Spring Arrangement Code C
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Port Restrictor Plug Code None
Gauge Ports Code None
Pressure [Max] 5000 psi
Spool Code 8
Rated Flow [Max] 175 gal/min
Coil Type Code U
Port Restrictor Plugs None
Crossover All Ports Open, Restricted
Electrical Options Code None
Pilot/Drain External Pilot/External Drain
Coil Type ISO 4400 (Din 43650) Connector
Pilot Valve Type CETOP 3, Standard Performance
Tank Port Rating 5000
EN Code None
Valve Type Standard-Duty
AC/DC AC
Manual Override Plain Override
Center Position P to T, A & B Blocked
Pilot Pressure Code E
Housing Code None
Spool Control Modification Code None
Surge Suppressor/Damper Code None
Pressure Port Check Valve Pressure N/A
Solenoid Double
Reducer Module Code None
Actuation Identification Solenoid A, Solenoid B
Design No. 10
Pilot Drain Code None
Overrides Plain Override Solenoid Ends
Actuator Type Solenoid
Manual Override Option Code None
Surge Suppressor/Damper None
NFPA Size D08
Solenoid Energization Code V
Compatible Fluids Petroleum Oil
Spool Indicator Switch Code None
Mounting Subplate/Manifold Mount
Gauge Port SAE-4
Response Type Code None
Mechanical Options None
Electrical Connection No Connector
Operation Pilot Operated
Body Material Ductile Iron
Seal Material Buna-N
Pilot Valve Type Code S
Pressure Port Check Valve Code None
Fluid Cleanliness 19/17/14 micron
Temperature Range [Max] 230 °F
Indicator Lights No
Solenoid Indicator Lights Code None
Temperature Range [Min] -40 °F
Response Type Standard Response
No. of Stages Two Stage
Mechanical Options Code None
Weight 35.0 LB