Skip to content Skip to navigation menu
Vickers by Danfoss02-329261

02-329261

Vickers D08 Solenoid Valve
Item #102087189
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329261
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Aluminum housings can be used for pressures up to 3,000 psi
  • Steel housings must be used for operating pressures above 3,000 psi
Reducer Module N/A
Solenoid Energization Code V
Response Type Standard Response
Reducer Module Code None
Pilot Valve Type Code S
Spool Spring Arrangement Code C
Pilot Valve Type CETOP 3, Standard Performance
Solenoid Indicator Lights Code None
EN Code None
Spool Indicator Switch Code None
Rated Flow [Max] 185 gal/min
Actuator Type Solenoid
NFPA Size D08
Electrical Connector Code None
Port Restrictor Plugs None
Pressure Port Check Valve Code None
Mechanical Options Code None
Center Position P to T, A & B Blocked
Valve Type Standard-Duty
Function 3-Position Spring Centered
Electrical Options None
Pressure [Max] 5000 psi
Spool Control Modification Code None
Crossover All Ports Open, Restricted
Overrides Plain Override Solenoid Ends
Tank Port Rating 5000
Seal Material Buna-N
Mechanical Options None
Coil Rating Code B
Model No. DG5V-8-S-8C-E-T-VM-FW-B-10
Port Restrictor Plug Code None
Indicator Lights No
Pilot/Drain External Pilot/Internal Drain
Gauge Ports Code None
Design No. 10
Pilot Drain Code T
Response Type Code None
Electrical Options Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Connection No Connector
Pressure Port Check Valve Pressure N/A
Spool Code 8
Coil Type Code F
Gauge Port SAE-4
Housing Code W
Operation Pilot Operated
Manual Override Plain Override
Pilot Pressure Code E
Manual Override Option Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Pressure Rating 5000 psi
Surge Suppressor/Damper None
Surge Suppressor/Damper Code None
Solenoid Double
AC/DC AC
Weight 35.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle