Vickers by Danfoss02-329229

02-329229

Vickers D08 Solenoid Valve
Item #101971264
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-329229
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Standard, QD-style HTD sprockets may not have the torque capacity for the higher rated HT150 belts.
Mounting Subplate/Manifold Mount
Actuation Identification Solenoid A, Solenoid B
Housing Code W
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Manual Override Plain Override
Solenoid Indicator Lights Code L
Port Restrictor Plug Code None
Operation Pilot Operated
Pressure Port Check Valve Pressure N/A
Pilot Drain Code None
Actuator Type Solenoid
Port Restrictor Plugs None
Response Type Standard Response
Pressure [Max] 5000 psi
Fluid Cleanliness 19/17/14 micron
Response Type Code None
Port T Pressure Rating 5000 psi
Spool Indicator Switch Code None
Pilot Valve Type Code S
Leakage Standard Performance
Electrical Options None
Body Material Ductile Iron
Rated Flow [Max] 175 gal/min
Coil Type Code F
Mechanical Options Code None
Spool Control Modification Code None
Seal Material Buna-N
Crossover All Ports Blocked
Performance Standard Performance
Indicator Lights Yes
Model No. DG5V-8-S-2N-M-FTWL-B-10
Spool Code 2
NFPA Size D08
Coil Rating Code B
Center Position All Ports Blocked
Spool Spring Arrangement Code N
Solenoid Double
Surge Suppressor/Damper Code None
Electrical Connector Code T
Valve Type Standard-Duty
Pilot Valve Type CETOP 3, Standard Performance
Pilot/Drain Internal Pilot/External Drain
Temperature Range [Max] 230 °F
Gauge Ports Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Overrides Plain Override Solenoid Ends
Pilot Pressure Code None
Tank Port Rating 5000
Reducer Module Code None
Mechanical Options None
Solenoid Energization Code None
Electrical Connection Wired Terminal Block
Gauge Port SAE-4
Compatible Fluids Petroleum Oil
Design No. 10
Function 3-Position Detented
Reducer Module No
Surge Suppressor/Damper None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Manual Override Option Code None
Pressure Port Check Valve Code None
No. of Stages Two Stage
EN Code None
AC/DC AC
Electrical Options Code None
Temperature Range [Min] -40 °F
Weight 35.0 LB