Skip to content Skip to navigation menu
Vickers by Danfoss02-329225

02-329225

Vickers D08 Solenoid Valve
Item #101977563
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329225
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Maintain 5 to 8 Nm (4 to 6 ft lb) maximum torque on valve tube nut
  • over-tightening may cause failure
Pilot Valve Type CETOP 3, Standard Performance
Center Position All Ports Blocked
Crossover All Ports Blocked
Response Type Standard Response
Spool Indicator Switch Code None
Design No. 10
Solenoid Energization Code None
Electrical Options None
Gauge Ports Code None
Coil Rating Code D
Reducer Module Code None
Coil Type DIN 43650
Pressure [Max] 5000 psi
Seal Material Buna-N
Reducer Module N/A
Pressure Port Check Valve Code None
Port Restrictor Plugs None
Actuator Type Solenoid
Pilot Valve Type Code S
Mechanical Options None
Response Type Code None
Manual Override Plain Override
Pilot Pressure Code None
Port T Pressure Rating 5000 psi
Gauge Port SAE-4
Pressure Port Check Valve Pressure N/A
Solenoid Double
Solenoid Indicator Lights Code None
Pilot Drain Code T
Function 3-Position Spring Centered
Electrical Connection No Connector
Electrical Connector Code None
Spool Control Modification Code None
Valve Type Standard-Duty
Electrical Options Code None
EN Code None
Model No. DG5V-8-S-2C-T-M-U-D-10
Surge Suppressor/Damper Code None
Voltage & Frequency 220/240 VAC - 50/60 Hz
Surge Suppressor/Damper None
Mechanical Options Code None
NFPA Size D08
Spool Code 2
Manual Override Option Code None
Indicator Lights No
Spool Spring Arrangement Code C
Pilot/Drain External Pilot/Internal Drain
Coil Type Code U
Rated Flow [Max] 185 gal/min
Tank Port Rating 5000
Overrides Plain Override Solenoid Ends
Port Restrictor Plug Code None
Housing Code None
AC/DC AC
Operation Pilot Operated
Weight 35.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison