Skip to content Skip to navigation menu
Vickers by Danfoss02-329178

02-329178

Vickers D08 Solenoid Valve
Item #101978006
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329178
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Mounting Subplate/Manifold Mount
Housing Code W
Rated Flow [Max] 175 gal/min
Spool Code 6
Manual Override Option Code None
Center Position P Blocked, A & B to T
Pilot/Drain External Pilot/External Drain
Spool Spring Arrangement Code C
Response Type Code None
Temperature Range [Max] 230 °F
Gauge Port SAE-4
Electrical Connector Code T
Actuation Identification Solenoid A, Solenoid B
Leakage Standard Performance
Operation Pilot Operated
Spool Control Modification Code None
AC/DC AC
Solenoid Indicator Lights Code L
Indicator Lights Yes
Design No. 10
Overrides Plain Override Solenoid Ends
Port Restrictor Plug Code None
Spool Indicator Switch Code None
Tank Port Rating 5000
EN Code None
Surge Suppressor/Damper None
Pilot Valve Type CETOP 3, Standard Performance
Manual Override Plain Override
Pilot Valve Type Code S
Coil Type Code F
Compatible Fluids Petroleum Oil
Crossover P Blocked, A or B to T
Performance Standard Performance
Coil Rating Code B
Pilot Pressure Code E
NFPA Size D08
Mechanical Options None
Pressure Port Check Valve Pressure N/A
Model No. DG5V-8-S-6C-E-M-FTWL-B-10
Body Material Ductile Iron
Actuator Type Solenoid
Electrical Options None
Gauge Ports Code None
Port Restrictor Plugs None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pressure [Max] 5000 psi
Reducer Module Code None
Function 3-Position Spring Centered
Solenoid Energization Code None
Seal Material Buna-N
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
No. of Stages Two Stage
Pilot Drain Code None
Reducer Module No
Temperature Range [Min] -40 °F
Response Type Standard Response
Valve Type Standard-Duty
Surge Suppressor/Damper Code None
Mechanical Options Code None
Solenoid Double
Port T Pressure Rating 5000 psi
Voltage & Frequency 110/120 VAC - 50/60 Hz
Fluid Cleanliness 19/17/14 micron
Electrical Connection Wired Terminal Block
Electrical Options Code None
Pressure Port Check Valve Code None
Weight 35.0 LB