- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Port Restrictor Plugs | None |
| Coil Type Code | F |
| Overrides | Plain Override Solenoid Ends |
| Mechanical Options | None |
| Indicator Lights | No |
| Port T Pressure Rating | 5000 psi |
| Pilot/Drain | External Pilot/Internal Drain |
| EN Code | None |
| Spool Indicator Switch Code | None |
| Spool Code | 6 |
| Response Type | Standard Response |
| Surge Suppressor/Damper Code | None |
| Electrical Options Code | None |
| Actuator Type | Solenoid |
| Pressure Port Check Valve Pressure | N/A |
| Tank Port Rating | 5000 |
| Gauge Port | SAE-4 |
| Leakage | Standard Performance |
| Solenoid Energization Code | None |
| Solenoid | Double |
| Function | 3-Position Spring Centered |
| Spool Center Condition | A Port and Double Offset sensing switch on B Port |
| NFPA Size | D08 |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Design No. | 10 |
| Electrical Connection | No Connector |
| Pilot Drain Code | None |
| Fluid Cleanliness | 19/17/14 micron |
| Model No. | DG5V-8-H-6C-M-FW-B-10 |
| Reducer Module Code | None |
| Seal Material | Buna-N |
| Gauge Ports Code | None |
| Performance | High Performance |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Mechanical Options Code | None |
| Rated Flow [Max] | 175 gal/min |
| Compatible Fluids | Petroleum Oil |
| Surge Suppressor/Damper | None |
| AC/DC | AC |
| Pressure [Max] | 5000 psi |
| Crossover | P Blocked, A or B to T |
| Electrical Options | None |
| Electrical Connector Code | None |
| Body Material | Gray Iron |
| Center Position | P Blocked, A & B to T |
| Spool Spring Arrangement Code | C |
| Port Restrictor Plug Code | None |
| Operation | Pilot Operated |
| Mounting | Subplate/Manifold Mount |
| Manual Override Option Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Coil Rating Code | B |
| Manual Override | Plain Override |
| Valve Type | Standard-Duty |
| Reducer Module | No |
| Spool Control Modification Code | None |
| Housing Code | W |
| Pilot Valve Type Code | H |
| No. of Stages | Two Stage |
| Response Type Code | None |
| Solenoid Indicator Lights Code | None |
| Pressure Port Check Valve Code | None |
| Pilot Valve Type | CETOP 3, High Performance |
| Pilot Pressure Code | None |
| Weight | 35.0 LB |