- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Body Material | Gray Iron |
| Pressure Port Check Valve Code | None |
| Coil Rating Code | B |
| Port Restrictor Plugs | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Electrical Options Code | None |
| EN Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Electrical Options | None |
| Gauge Ports Code | None |
| Response Type Code | None |
| Manual Override Option Code | None |
| Spool Indicator Switch Code | None |
| Compatible Fluids | Petroleum Oil |
| AC/DC | AC |
| Spool Control Modification Code | None |
| Reducer Module Code | None |
| Model No. | DG5V-8-H-6C-M-FW-B-10 |
| Design No. | 10 |
| Spool Center Condition | A Port and Double Offset sensing switch on B Port |
| Pressure Port Check Valve Pressure | N/A |
| Operation | Pilot Operated |
| No. of Stages | Two Stage |
| Surge Suppressor/Damper Code | None |
| Tank Port Rating | 5000 |
| Spool Spring Arrangement Code | C |
| NFPA Size | D08 |
| Pilot Valve Type | CETOP 3, High Performance |
| Performance | High Performance |
| Valve Type | Standard-Duty |
| Rated Flow [Max] | 175 gal/min |
| Spool Code | 6 |
| Fluid Cleanliness | 19/17/14 micron |
| Port Restrictor Plug Code | None |
| Solenoid Indicator Lights Code | None |
| Indicator Lights | No |
| Solenoid | Double |
| Solenoid Energization Code | None |
| Pilot Drain Code | None |
| Surge Suppressor/Damper | None |
| Leakage | Standard Performance |
| Electrical Connector Code | None |
| Housing Code | W |
| Pilot/Drain | External Pilot/Internal Drain |
| Pressure [Max] | 5000 psi |
| Manual Override | Plain Override |
| Coil Type Code | F |
| Pilot Pressure Code | None |
| Mechanical Options Code | None |
| Center Position | P Blocked, A & B to T |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Port T Pressure Rating | 5000 psi |
| Overrides | Plain Override Solenoid Ends |
| Function | 3-Position Spring Centered |
| Crossover | P Blocked, A or B to T |
| Actuator Type | Solenoid |
| Response Type | Standard Response |
| Mounting | Subplate/Manifold Mount |
| Pilot Valve Type Code | H |
| Electrical Connection | No Connector |
| Reducer Module | No |
| Seal Material | Buna-N |
| Gauge Port | SAE-4 |
| Mechanical Options | None |
| Weight | 35.0 LB |