Vickers D08 Solenoid Valve
Item #101978007
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329163
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Mixing grid coupling components from different manufacturers may cause premature failure and possible personal injury or property damage from flying debris
Spool Spring Arrangement Code C
Pressure [Max] 5000 psi
AC/DC AC
Mounting Subplate/Manifold Mount
Leakage High Performance
Performance High Performance
Design No. 10
Pilot Valve Type CETOP 3, High Performance
Pilot Drain Code T
Mechanical Options Code None
Function 3-Position Spring Centered
Model No. DG5V-8-H-6C-E-T-M-FW-B-10
Center Position P Blocked, A & B to T
NFPA Size D08
Pressure Port Check Valve Pressure N/A
Port Restrictor Plugs None
No. of Stages Two Stage
Spool Code 6
Housing Code W
Port Restrictor Plug Code None
Pilot Pressure Code E
Electrical Connection No Connector
Crossover P Blocked, A or B to T
Actuator Type Solenoid
Temperature Range [Max] 230 °F
Solenoid Double
Coil Type Code F
Solenoid Energization Code None
Surge Suppressor/Damper None
Pilot Valve Type Code H
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mechanical Options None
Tank Port Rating 5000
Reducer Module Code None
Pressure Port Check Valve Code None
Electrical Options None
Electrical Options Code None
Electrical Connector Code None
Overrides Plain Override Solenoid Ends
Surge Suppressor/Damper Code None
Port T Pressure Rating 5000 psi
Response Type Standard Response
Rated Flow [Max] 175 gal/min
Reducer Module No
EN Code None
Gauge Port SAE-4
Solenoid Indicator Lights Code None
Indicator Lights No
Operation Pilot Operated
Temperature Range [Min] -40 °F
Spool Control Modification Code None
Manual Override Option Code None
Valve Type Standard-Duty
Spool Indicator Switch Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Actuation Identification Solenoid A, Solenoid B
Coil Rating Code B
Seal Material Buna-N
Manual Override Plain Override
Fluid Cleanliness 19/17/14 micron
Response Type Code None
Gauge Ports Code None
Pilot/Drain External Pilot/Internal Drain
Compatible Fluids Petroleum Oil
Body Material Ductile Iron
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Weight 35.0 LB