Vickers D08 Solenoid Valve
Item #101978007
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329163
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Mixing grid coupling components from different manufacturers may cause premature failure and possible personal injury or property damage from flying debris
Port Restrictor Plug Code None
Mounting Subplate/Manifold Mount
Coil Type Code F
Body Material Ductile Iron
Pilot Drain Code T
Mechanical Options None
Manual Override Option Code None
Leakage High Performance
Pressure [Max] 5000 psi
Response Type Standard Response
Coil Rating Code B
Actuation Identification Solenoid A, Solenoid B
Function 3-Position Spring Centered
Electrical Connection No Connector
Reducer Module No
NFPA Size D08
Electrical Options None
Port T Pressure Rating 5000 psi
Mechanical Options Code None
Port Restrictor Plugs None
Spool Indicator Switch Code None
Rated Flow [Max] 175 gal/min
Spool Code 6
Spool Spring Arrangement Code C
Seal Material Buna-N
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Options Code None
EN Code None
Surge Suppressor/Damper Code None
Reducer Module Code None
Pressure Port Check Valve Code None
Spool Control Modification Code None
Pilot Pressure Code E
Tank Port Rating 5000
Center Position P Blocked, A & B to T
Actuator Type Solenoid
Indicator Lights No
Operation Pilot Operated
Gauge Ports Code None
Electrical Connector Code None
Performance High Performance
Housing Code W
Pilot Valve Type Code H
Voltage & Frequency 110/120 VAC - 50/60 Hz
Model No. DG5V-8-H-6C-E-T-M-FW-B-10
Pilot/Drain External Pilot/Internal Drain
Surge Suppressor/Damper None
Pilot Valve Type CETOP 3, High Performance
Manual Override Plain Override
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Design No. 10
Temperature Range [Max] 230 °F
Solenoid Indicator Lights Code None
Pressure Port Check Valve Pressure N/A
Gauge Port SAE-4
Crossover P Blocked, A or B to T
Solenoid Double
Temperature Range [Min] -40 °F
No. of Stages Two Stage
Solenoid Energization Code None
Compatible Fluids Petroleum Oil
Response Type Code None
Valve Type Standard-Duty
Fluid Cleanliness 19/17/14 micron
AC/DC AC
Overrides Plain Override Solenoid Ends
Weight 35.0 LB