Vickers D08 Solenoid Valve
Item #101978007
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329163
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Mixing grid coupling components from different manufacturers may cause premature failure and possible personal injury or property damage from flying debris
Leakage High Performance
Model No. DG5V-8-H-6C-E-T-M-FW-B-10
Valve Type Standard-Duty
Pilot Drain Code T
Gauge Ports Code None
Housing Code W
Response Type Code None
Electrical Options None
Spool Indicator Switch Code None
Indicator Lights No
Overrides Plain Override Solenoid Ends
Port Restrictor Plugs None
Electrical Connector Code None
Performance High Performance
EN Code None
Port Restrictor Plug Code None
Solenoid Energization Code None
Coil Rating Code B
Manual Override Plain Override
Function 3-Position Spring Centered
Spool Code 6
Mounting Subplate/Manifold Mount
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Surge Suppressor/Damper None
Seal Material Buna-N
Crossover P Blocked, A or B to T
Mechanical Options None
Temperature Range [Max] 230 °F
Pressure Port Check Valve Pressure N/A
Spool Control Modification Code None
Mechanical Options Code None
Pilot Pressure Code E
Rated Flow [Max] 175 gal/min
Coil Type Code F
Pilot Valve Type CETOP 3, High Performance
Electrical Options Code None
Operation Pilot Operated
No. of Stages Two Stage
NFPA Size D08
Pilot/Drain External Pilot/Internal Drain
Surge Suppressor/Damper Code None
Body Material Ductile Iron
Spool Spring Arrangement Code C
Electrical Connection No Connector
Fluid Cleanliness 19/17/14 micron
Voltage & Frequency 110/120 VAC - 50/60 Hz
Temperature Range [Min] -40 °F
Reducer Module Code None
Design No. 10
Pilot Valve Type Code H
Gauge Port SAE-4
Pressure Port Check Valve Code None
Reducer Module No
Manual Override Option Code None
Response Type Standard Response
Center Position P Blocked, A & B to T
Actuator Type Solenoid
Tank Port Rating 5000
Solenoid Indicator Lights Code None
AC/DC AC
Port T Pressure Rating 5000 psi
Solenoid Double
Pressure [Max] 5000 psi
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Actuation Identification Solenoid A, Solenoid B
Compatible Fluids Petroleum Oil
Weight 35.0 LB